Skip to main content
Schneider Electric A9D56825 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D56825 Acti9 iC60 RCBO, 25 A, 30 mA, Ty

MPNA9D56825
Active

Schneider Electric Acti9 iC60 RCBO, A9D56825, 1P+N, 25 A, 30 mA, B-curve, 10 kA, 240 V AC.

$195.88Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D56825 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication Fault indication
A9D56825 — Electrical Ratings
ParameterValue
Rated current (In)25 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryII
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D56825 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H RCBO PoN
A9D56825 — Mechanical
ParameterValue
Mounting supportIsobar B Isobar A
Mounting modePlug-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...10 mm² flexible Screw clamp terminal (top) 1...25 mm² rigid Screw clamp terminal (bottom) 1...16 mm² rigid Plug-on neutral (upstream)
Wire stripping length14 mm for top connection 13 mm for bottom connection
Terminal tightening torque3.5 N.m top 2 N.m bottom
Width18 mm
Height110 mm
Depth72 mm
A9D56825 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D56825 — Approvals
ParameterValue
StandardsIEC 61009-2-2 IEC 61009-1 BS EN 61009-1

Product details

The Schneider Electric A9D56825 is an Acti9 iC60 RCBO — a combined residual current breaker with overcurrent protection, integrating earth-leakage and thermal-magnetic trip in a single 18 mm module. Rated 25 A at 50 °C with a 30 mA earth-leakage sensitivity, it protects a single pole (1P + Ns) on TN earthing systems.

Mounts on a DIN rail via the plug-on mechanism, occupying 2 pitches of 9 mm (18 mm total width). The top screw-clamp terminal accepts up to 25 mm² rigid or 16 mm² flexible; the bottom terminal accepts up to 16 mm² rigid or 10 mm² flexible. Tightening torque is 3.5 N·m top and 2 N·m bottom. Wire stripping length is 14 mm for the top connection and 13 mm for the bottom.

Rated breaking capacity is 10 kA Icn at 240 V AC, 50/60 Hz, conforming to IEC 61009-2-2. The device also complies with IEC 61009-1 and BS EN 61009-1. Electrical durability is 5000 cycles; mechanical durability is 20,000 cycles. IP20 rated (IP40 in modular enclosure). Overvoltage category II. Tropicalisation class 2. Local signalling includes ON/OFF and fault indication via the toggle.

Frequently asked questions

Where can I buy A9D56825 and how do I get a price?

The A9D56825 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is A9D56825's listed depth?

The A9D56825 has a depth of 72 mm.

What is A9D56825's listed range?

The A9D56825 belongs to the Acti9 range.

What compliance documentation does this brand provide for A9D56825?

The A9D56825 complies with IEC 61009-2-2, IEC 61009-1, and BS EN 61009-1. It is rated IP20 (IP40 in modular enclosure) per IEC 60529.

MPN
A9D56825