Skip to main content
Schneider Electric A9D57432 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D57432 Acti9 iC60 RCBO, 32A, 30mA, 4P,

MPNA9D57432
Active

Schneider Electric Acti9 iC60 RCBO, 4P, 32 A rated current, 30 mA earth-leakage sensitivity, C-curve, 6 kA breaking capacity, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9D57432 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D57432 — Electrical Ratings
ParameterValue
Rated current (In)32 A
Rated operational voltage (Ue)380...415 V AC 50 Hz
Poles description4P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D57432 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60 RCBO
A9D57432 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m
Width72 mm
Height86 mm
Depth78 mm
A9D57432 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D57432 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1

Product details

Its 32 A rated current (In) and C-curve magnetic trip (5 to 10 x In) mean it is sized for general-purpose distribution circuits feeding mixed resistive and moderate-inductive loads, such as lighting, socket outlets, and small motorized equipment, where the C-curve provides tolerance for inrush without nuisance tripping. The 30 mA earth-leakage sensitivity (IΔn) provides personnel protection against direct contact, per the requirements of IEC 60364 for socket-outlet circuits and final subcircuits in residential and commercial installations. Integrated earth-leakage protection means no separate RCCB module is needed upstream — this single unit handles both overcurrent and ground-fault detection. Breaking capacity is 6 kA Icn / Icu at 380–415 V AC, 50 Hz, conforming to EN/IEC 61009-2-1 and EN/IEC 60947-2. This is the standard interrupting rating for final distribution boards in most European domestic and light commercial panels. For installations with higher prospective fault current, selectivity with an upstream MCCB or fuse must be verified. The thermal-magnetic trip unit provides time-delayed overload protection (thermal bimetal) and instantaneous short-circuit protection (magnetic solenoid). Limitation class 1 per EN/IEC 61009-2-1 means the device limits let-through energy to a level that protects downstream wiring under fault conditions.

Deployment and integration

Clip-on mounting to DIN rail (EN 60715) with a 9 mm pole pitch. The 4-pole unit occupies 8 x 9 mm = 72 mm of rail width. IP40 in a distribution enclosure, IP20 for the terminals — suitable for installation within a panel or consumer unit. Local signalling via toggle position: ON, OFF, and fault-trip indication. The toggle provides manual control and visual status at the panel face.

Quality labels include KEMA-KEUR, NF, IMQ, and VDE — these marks certify compliance with the applicable EN/IEC standards and are accepted across most European and many international regulatory jurisdictions.

Durability and environmental ratings

These figures reflect the expected service life under rated load conditions and are consistent with a premium RCBO intended for distribution duty.

Frequently asked questions

What compliance documentation does this brand provide for A9D57432?

The A9D57432 carries KEMA-KEUR, NF, IMQ, and VDE quality labels, and is certified to EN/IEC 60947-2 and EN/IEC 61009-2-1. RoHS and REACH compliance documentation is standard for Schneider Electric Acti9 products; request these from the distributor at quote time.

MPN
A9D57432