Schneider Electric A9D61806 Acti9 iC60 RCBO, 6A C-curve, 30m

MPNA9D61806
Active

Schneider Electric Acti9 iC60 RCBO, residual current breaker with overcurrent protection, 1P + Ns, 6 A rated, C-curve, 30 mA earth leakage, 6 kA breaking capacity, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9D61806 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D61806 — Electrical Ratings
ParameterValue
Rated current (In)6 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D61806 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60N RCBO
A9D61806 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D61806 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9D61806 — Approvals
ParameterValue
StandardsIEC 61009-1 IEC 61009-2-2 AS/NZS 61009.1

Product details

It integrates a 6 A thermal-magnetic MCB (C-curve) and a 30 mA earth leakage trip into one clip-on DIN rail unit, saving a full module width compared to separate MCB + RCCB. The 6 A rating at 50 °C means it protects a final subcircuit drawing up to that continuous current; the C-curve (magnetic trip at 5–10× In) handles motor and lighting inrush without nuisance tripping. The 30 mA earth leakage sensitivity covers personnel protection (indirect contact) per IEC 61009-1. Breaking capacity is 6 kA Icn at 230/240 V AC — enough for most domestic and light commercial distribution boards, but check the prospective fault current at the point of installation; if it exceeds 6 kA, step up to the iC60H or iC60L variants.

Clip-on mount to standard 35 mm DIN rail. The 18 mm width (2 x 9 mm pitches) and 77.5 mm depth fit standard consumer unit and distribution board cutouts. Neutral is on the left (1P + Ns configuration). Tightening torque 3.5 N.m top, 2 N.m bottom. IP20 finger-safe — intended for enclosed panel use only, not washdown environments.

Frequently asked questions

What is the breaking capacity of A9D61806?

6 kA Icn at 230/240 V AC, 50/60 Hz. This is the rated short-circuit breaking capacity per IEC 61009-1. For installations with higher prospective fault current, consider the iC60H (10 kA) or iC60L (15 kA) variants in the same footprint.

What standards does A9D61806 comply with?

IEC 61009-1, IEC 61009-2-2, and AS/NZS 61009.1. These cover the requirements for RCBOs — combined overcurrent and residual current protection — for household and similar installations.

What is the earth leakage sensitivity of A9D61806?

30 mA, integrated into the unit. This provides personnel protection against indirect contact and is the standard sensitivity for final circuits in most residential and light commercial applications.

Where can I buy A9D61806 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
A9D61806