Schneider Electric A9D69610
MPNA9D69610
Active
Residual current breaker with overcurrent protection (RCBO), Acti9 iDPN N Vigi, 1P+N, 10A, B curve, 6000A, A type, 300mA
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
| Parameter | Value |
|---|---|
| Control type | Toggle |
| Network type | AC |
| Product or component type | Residual current breaker with overcurrent protection (RCBO) |
| Voltage | 400 V AC 50 Hz |
| [Ue] rated operational voltage | 230...240 V AC 50 Hz |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Breaking capacity | 6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 |
| Current | 10 A |
| Residual current tripping technology | Voltage independent |
| [Ics] rated service breaking capacity | 6000 A 100 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 |
| Network frequency | 50 Hz |
| Poles description | 1P + N |
All specifications
| Parameter | Value |
|---|---|
| Number of protected poles | 1 |
| IP degree of protection | IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529 |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| Connection pitch | 9 mm between phase and neutral |
| Wire stripping length | 15 mm for top or bottom connection |
| Connections - terminals | Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule |
| Pollution degree | 3 |
| Relative humidity | 95 % at 55 °C |
| Depth | 73 mm |
| Width | 36 mm |
| Color | White |
| Height | 85 mm |
| Product weight | 125 g |
| Electrical durability | 20000 cycles |
| Mechanical durability | 20000 cycles |
| Standards | EN/IEC 61009-2-1 |
| Range | Acti9 |
| Curve code | B |
| 9 mm pitches | 4 |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Limitation class | 3 conforming to EN/IEC 61009-2-1 |
| Local signalling | ON, OFF, fault trip |
| Neutral position | Left |
| Device short name | iDPN N Vigi |
| Tightening torque | 2 N.m top or bottom |
| Device application | Distribution |
| Overvoltage category | III conforming to IEC 60364 |
| Trip unit technology | Thermal-magnetic |
| Magnetic tripping limit | 3...5 x In |
| Earth-leakage protection | Integrated |
| Device location in system | Outgoer |
| Earth-leakage sensitivity | 300 mA |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Contact position indicator | Yes |
| Locking options description | Padlocking device |
| Electromagnetic compatibility | 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 |
| Earth-leakage protection class | Type A |
| Rated breaking and making capacity | Idm 6000 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 |
| Ambient air temperature for storage | -40...85 °C |
| Earth-leakage protection time delay | Instantaneous |
| Ambient air temperature for operation | -25...60 °C |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
MPN