Skip to main content
Schneider Electric A9D83625T — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D83625T Acti9 ISPN Vigi RCBO, C-Curve 2

MPNA9D83625T
Active

Schneider Electric Acti9 ISPN Vigi RCBO, 1P+N, 25 A, C-curve, 30 mA earth-leakage sensitivity, 10 kA breaking capacity at 230/240 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D83625T — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D83625T — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)230/240 V AC 50 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability6000 cycles
Mechanical durability (operating cycles)10000 cycles
A9D83625T — Identification
ParameterValue
Product nameISPN Vigi
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
A9D83625T — Mechanical
ParameterValue
Mounting supportDIN rail Chassis
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsTunnel type terminal (upstream) 1...25 mm² rigid Tunnel type terminal (downstream) 1...16 mm² rigid Tunnel type terminal (upstream) 1...16 mm² flexible Tunnel type terminal (downstream) 1...10 mm² flexible
Wire stripping length13 mm for downstream connection 14 mm for upstream connection
Terminal tightening torque3.5 N.m upstream 2 N.m downstream
Width18 mm
A9D83625T — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2
A9D83625T — Approvals
ParameterValue
StandardsAS/NZS 61009.1

Product details

It combines a C-curve thermal-magnetic MCB and a 30 mA earth-leakage module in a single 18 mm wide unit that clips onto a DIN rail.

The 25 A rated current (In) and C-curve magnetic trip (5 to 10 x In) mean this RCBO handles general-purpose loads like lighting, socket outlets, and small appliances that produce moderate inrush — the C curve is the standard choice for mixed resistive-inductive circuits in commercial fit-outs. The 30 mA earth-leakage sensitivity provides personal protection against direct contact, meeting the threshold required by most wiring regulations for socket circuits. The limitation class 3 rating means the device limits let-through energy under fault, reducing stress on downstream wiring. The tunnel-type terminals accept ferruled stranded as well; strip length is 13 mm downstream and 14 mm upstream. Mechanical durability is 10 000 cycles, electrical durability 6 000 cycles.

Width is 18 mm (2 x 9 mm pitches). IP20 rated, so suitable for enclosure interiors but not washdown zones. Provision for padlocking with a 4 mm padlock for lockout/tagout during maintenance.

Certified to AS/NZS 61009.1, the Australian/New Zealand standard for RCBOs. The Acti9 range is Schneider Electric's current-generation DIN-rail protection platform, so this part carries the manufacturer's standard warranty and technical support. Pollution degree 2, tropicalisation class 2.

Frequently asked questions

What is the A9D83625T used for?

It is a combined overcurrent and earth-leakage protection device (RCBO) for 1P+N circuits. Use it on 230/240 V AC socket circuits, lighting circuits, and small appliance feeds where both short-circuit, overload, and 30 mA earth-leakage protection are required in a single 18 mm DIN-rail module.

Where can I buy the A9D83625T?

This part is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm delivery schedule.

What is the breaking capacity of the A9D83625T?

10 000 A Icn at 230/240 V AC, 50 Hz. That is the rated short-circuit breaking capacity the device can safely interrupt under fault conditions.

MPN