Skip to main content
Schneider Electric A9DC3713 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DC3713 Acti9 iCV40 RCBO, 13 A, 30 mA, C

MPNA9DC3713
Active

Schneider Electric Acti9 iCV40 RCBO, 13 A, 30 mA earth-leakage, C-curve, 3P+N, 6 kA Icn at 400 V AC, DIN rail mount, thermal-magnetic trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9DC3713 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication Fault indication
A9DC3713 — Electrical Ratings
ParameterValue
Rated current (In)13 A
Rated operational voltage (Ue)400 V AC 50/60 Hz
Poles description3P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)440 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DC3713 — Identification
ParameterValue
Product nameActi9 iCV40
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiCV40N
A9DC3713 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules10
Terminal connectionsTunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width90 mm
Height93 mm
Depth73 mm
A9DC3713 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Operating altitude2000 m
A9DC3713 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The Schneider Electric A9DC3713 is an Acti9 iCV40 RCBO — a combined residual-current circuit breaker with overcurrent protection, rated 13 A with 30 mA earth-leakage sensitivity, C-curve, 3P+N poles, and a breaking capacity of 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1.

Tunnel-type terminals accept 1…16 mm² rigid or 1…10 mm² flexible cable; tighten to 2 N·m. IP20 rated (IP40 in modular enclosure), so it suits enclosed distribution boards — not outdoor or washdown locations.

Rated for 20000 electrical and 20000 mechanical cycles. Pollution degree 3, overvoltage category III per IEC 60364, operating altitude up to 2000 m, relative humidity 95 % at 55 °C.

Frequently asked questions

What is A9DC3713 used for?

The A9DC3713 is a combined RCBO (residual-current circuit breaker with overcurrent protection) used as an outgoer in distribution boards to protect final circuits against overloads, short-circuits, and earth faults.

What are the key ratings of A9DC3713?

Rated current 13 A, earth-leakage sensitivity 30 mA, C-curve (magnetic trip 5–10× In), breaking capacity 6000 A Icn at 400 V AC, 3P+N poles, thermal-magnetic trip.

Where can I buy A9DC3713?

The A9DC3713 is sourced and quoted to order against an RFQ through independent distribution; current pricing and availability are confirmed at quote time.

MPN
A9DC3713