Skip to main content
Schneider Electric A9F05370 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F05370 Acti9 iC60 D Curve MCB, 0.5 A 3P

MPNA9F05370
Obsolete

Schneider Electric Acti9 iC60, IC60N, miniature circuit-breaker, 3P, D curve, 0.5 A rated current, 50 kA Icu breaking capacity, DIN rail mount, white.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F05370 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F05370 — Ratings
ParameterValue
Rated current (In)0.5 A
Poles configuration3P
Number of protected poles3
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F05370 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F05370 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6
A9F05370 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F05370 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F05370 is an Acti9 iC60 miniature circuit-breaker (IC60N) rated at 0.5 A with a D tripping curve. It protects a 3-pole AC distribution circuit, and the D-curve magnetic trip at 12 x In (±20%) means it handles high inrush loads like small transformers or motor starters without nuisance tripping — the right call for a motor control panel or industrial machine supply.

Snaps onto DIN rail (6 x 9 mm pitches), occupies 54 mm width. IP20 rated — panel-internal use, not washdown.

Breaking capacity is 50 kA Icu at 220…240 V and 380…415 V AC per EN/IEC 60947-2, dropping to 25 kA at 440 V and 10 kA Icn at 400 V per EN/IEC 60898-1. That 50 kA rating at common industrial voltages gives solid SCCR headroom for a panel fed from a transformer of moderate size — you can coordinate downstream without cascading upstream.

Rated insulation voltage 500 V AC, overvoltage category IV, pollution degree 3. Suitability for isolation confirmed to both standards — the toggle and contact position indicator give a visible air gap when off. Separate earth-leakage block can be added alongside if needed.

Frequently asked questions

What is the breaking capacity of A9F05370?

50 kA Icu at 220…240 V and 380…415 V AC per EN/IEC 60947-2, 25 kA Icu at 440 V, and 10 kA Icn at 400 V per EN/IEC 60898-1.

What is the closest alternative to A9F05370 in the Acti9 range?

Within the Acti9 iC60 family, the key variant difference is the curve code. The A9F05370 uses a D curve (12 x In magnetic trip) for high-inrush loads; a C-curve sibling (5 to 10 x In) would be the alternative for general-purpose distribution where inrush is lower. No pin-compatible alternate from another series is documented here.

What compliance standards does A9F05370 meet?

Certified to EN/IEC 60947-2 and EN/IEC 60898-1. Tropicalisation class 2 per IEC 60068-1. IP20 per IEC 60529. Pollution degree 3 and overvoltage category IV per EN/IEC 60947-2.

Where can I buy A9F05370 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
A9F05370