Skip to main content
Schneider Electric A9F05402 — Miniature Circuit Breakers (MCB)

A9F05402 Acti9 iC60N MCB, 2 A, Curve D, 4P, 50 kA

MPNA9F05402
Obsolete

Schneider Electric Acti9 iC60N, A9F05402, miniature circuit breaker, 4P, 2 A, curve D, 50 kA Icu at 400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F05402 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F05402 — Ratings
ParameterValue
Rated current (In)2 A
Poles configuration4P
Number of protected poles4
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F05402 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F05402 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8
A9F05402 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F05402 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F05402 is a Schneider Electric Acti9 iC60N miniature circuit breaker — 4 poles, 2 A rated current, curve D, thermal-magnetic trip. The 50 kA Icu at 400 V AC (EN/IEC 60947-2) means it can safely interrupt a fault up to 50,000 A without welding or bursting — that is high fault-current headroom for industrial panelboards fed by large transformers. The 10 kA Icn at 400 V (EN/IEC 60898-1) is the domestic/light-commercial rating; the 50 kA Icu is what matters for industrial coordination.

Snaps onto standard DIN rail (mounting support: DIN rail). Occupies 8 x 9 mm pitches (72 mm wide). Depth is 78.5 mm, height 91 mm — fits standard distribution boards. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible wire; tightening torque 2 N.m. Strip length 14 mm. IP20 finger-safe. Overvoltage category IV (mains entry). Suitable for isolation per both standards — the contact position indicator and trip indicator confirm open contacts visually.

Frequently asked questions

How do I get current pricing and availability for A9F05402?

Submit an RFQ through this listing. We source the part through independent distribution; price and stock are confirmed at quote time — no numbers are published here.

What is A9F05402's rated current and breaking capacity?

Rated current is 2 A. Breaking capacity: 50 kA Icu at 400 V AC (EN/IEC 60947-2) and 10 kA Icn at 400 V (EN/IEC 60898-1).

What does curve D mean on this MCB?

Curve D means the magnetic trip operates at 12× In ±20 % — designed for loads with high inrush current like small motors or transformers, avoiding nuisance trips on startup.

MPN