Schneider Electric A9F06463 — Miniature Circuit Breakers (MCB)

Schneider A9F06463 Acti9 iC60H MCB, 63 A, 4P, B-Curve

MPNA9F06463
Obsolete

Schneider Electric Acti9 iC60H, miniature circuit breaker, 4P, 63 A, B-curve, 42 kA Icu at 12-133 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F06463 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F06463 — Ratings
ParameterValue
Rated current (In)63 A
Poles configuration4P
Number of protected poles4
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F06463 — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F06463 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8
A9F06463 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F06463 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F06463 is a 63 A, 4-pole miniature circuit breaker from the Acti9 iC60H series, with a B-curve trip characteristic. Rated at 63 A, this MCB handles the full load current of a submain or a large branch circuit.

The breaking capacity is 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V AC, and 15 kA at 380–415 V AC (per EN/IEC 60947-2). At 400 V AC, the Icn is 15 kA per EN/IEC 60898-1. This dual-rated MCB meets both the industrial (60947-2) and domestic/light commercial (60898-1) standards, so it can be specified in a panel that requires industrial coordination or a residential load center.

Integration notes

Depth is 78.5 mm, height 91 mm. Terminals accept 1–35 mm² rigid or 1–25 mm² flexible conductors; tightening torque is 3.5 N.m.

Frequently asked questions

How do I get current pricing and availability for A9F06463?

Pricing and availability are confirmed at quote time. Submit an RFQ through the storefront; the part is sourced to order through independent distribution.

What is the closest pin-compatible alternative to A9F06463 in this component family?

Within the Acti9 iC60H range, the closest alternative would be a different current rating or curve code — for example, a 63 A C-curve (A9F06464) if you need higher inrush tolerance. All iC60H breakers share the same footprint, terminal layout, and DIN-rail mounting.

What compliance documentation does this brand provide for A9F06463?

The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1, with suitability for isolation. It also meets tropicalisation class 2 per IEC 60068-1. RoHS and REACH declarations are standard for Schneider Electric Acti9 products.

MPN
A9F06463