Schneider Electric A9F07470 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F07470 Acti9 iC60H MCB, 4P, 0.5 A, C-Cu

MPNA9F07470
Obsolete

Schneider Electric Acti9 iC60H, A9F07470, miniature circuit breaker, 4P, 0.5 A rated current, C-curve, 70 kA breaking capacity, DIN rail mount, white.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F07470 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F07470 — Ratings
ParameterValue
Rated current (In)0.5 A
Poles configuration4P
Number of protected poles4
Breaking capacity70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F07470 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F07470 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8
A9F07470 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F07470 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

Breaking capacity and dual-standard certification

The Schneider Electric A9F07470 is an Acti9 iC60H miniature circuit breaker rated 0.5 A, 4-pole, with a C-curve magnetic trip at 8 x In ±20 %. Its headline figure is the 70 kA breaking capacity (Icu) at 220…240 V AC and 380…415 V AC per EN/IEC 60947-2, dropping to 50 kA at 440 V AC and 15 kA Icn at 400 V per EN/IEC 60898-1. That 70 kA rating means it clears high-fault currents typical of industrial distribution panels without upstream cascading — the SCCR headroom is real for a 0.5 A device.

Dual-certified to EN/IEC 60898-1 (household / commercial) and EN/IEC 60947-2 (industrial). The 60947-2 certification gives you Category A utilization (no intentional short-time delay) and pollution degree 3 — meaning it's rated for the conductive dust and humidity you'd see in a factory floor panel, not just a clean office board. Overvoltage category IV suits main-distribution-board installation. The C-curve (8 x In magnetic trip) is standard for moderate inrush loads — think small contactor coils, control transformers, or lighting banks. At 0.5 A, this is sized for a control-circuit feeder, not a motor branch.

Panel integration and lifecycle

Mounts on standard DIN rail (9 mm pitch, 8 modules wide). Terminals accept 1…25 mm² rigid or 1…16 mm² flexible on double terminals top and bottom — torque to 2 N·m. The white housing and trip-indicator flag give clear visual status.

Frequently asked questions

What is A9F07470's breaking capacity?

70 kA Icu at 220…240 V AC and 380…415 V AC per EN/IEC 60947-2, 50 kA at 440 V AC, and 15 kA Icn at 400 V per EN/IEC 60898-1.

Where can I buy A9F07470?

The A9F07470 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does A9F07470 carry?

The breaker is certified to EN/IEC 60898-1 and EN/IEC 60947-2, with a pollution degree of 3, overvoltage category IV, and tropicalisation class 2 per IEC 60068-1. It is suitable for isolation per both standards.

MPN