Specifications

A9F68301 — Identification
ParameterValue
Product nameActi9 iT60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F68301 — Ratings
ParameterValue
Rated current (In)1 A
Poles configuration3P
Number of protected poles3
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F68301 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
A9F68301 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeRemovable comb busbar installed
Control typeToggle
Terminal connection typeSingle terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Number of 9 mm pitches6
A9F68301 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 B conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 %
Tropicalisation class2 conforming to EN/IEC 60068-2-78
A9F68301 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F68301 is a 3-pole miniature circuit breaker from the Acti9 iT60 series, rated at 1 A with a C trip curve.

This breaker delivers 50 kA Icu at 415 V AC (per EN/IEC 60947-2), which means it can safely interrupt a fault current up to 50,000 A without welding its contacts or rupturing the case. At 440 V AC the rating drops to 25 kA Icu, and at 400 V AC the Icn per EN/IEC 60898-1 is 10 kA — still adequate for most sub-distribution boards.

Trip curve and selectivity

The C curve means the magnetic trip threshold is 8 x In (±20 %), so for this 1 A breaker the instantaneous trip point sits between 6.4 A and 9.6 A. That suits loads with moderate inrush — think control transformers, contactor coils, or small lighting circuits — while still providing enough headroom to avoid nuisance tripping on startup. The thermal-magnetic trip unit handles the overload side; the thermal element responds to sustained overcurrents, the magnetic element to short-circuits.

Standards and isolation suitability

It is marked suitable for isolation per both standards, meaning you can rely on the visible contact position indicator to confirm the circuit is dead before working downstream.

Frequently asked questions

What is A9F68301's breaking capacity at 415 V AC?

The A9F68301 has a breaking capacity of 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2.

What is the closest alternative to A9F68301 in the Acti9 range?

Within the Acti9 iT60 series, the closest alternative would be a different current rating or pole configuration — the A9F68301 is a 1 A, 3-pole, C-curve variant. For a 1 A, 1-pole version, the order code would differ by the pole count designation. No pin-compatible drop-in replacement exists outside the Acti9 iT60 family without verifying the mounting and busbar compatibility.

Where can I buy A9F68301 and how is it quoted?

The A9F68301 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN