Schneider Electric A9F68340 — Miniature Circuit Breakers (MCB)

Schneider A9F68340 Acti9 iT60 MCB, 40A C-Curve 3P 36kA

MPNA9F68340
Obsolete

Schneider Electric Acti9 iT60, A9F68340, miniature circuit breaker, 40 A, curve C, 3P, 36 kA breaking capacity at 133 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F68340 — Identification
ParameterValue
Product nameActi9 iT60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F68340 — Ratings
ParameterValue
Rated current (In)40 A
Poles configuration3P
Number of protected poles3
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F68340 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
A9F68340 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeRemovable comb busbar installed
Control typeToggle
Terminal connection typeSingle terminal (top or bottom) 1...35 mm² rigid Single terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Number of 9 mm pitches6
A9F68340 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 B conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 %
Tropicalisation class2 conforming to EN/IEC 60068-2-78
A9F68340 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider A9F68340 is a 40 A, C-curve, 3-pole miniature circuit breaker from the Acti9 iT60 series, rated for both AC and DC networks. At 400 V AC, the Icn under EN/IEC 60898-1 is 10 kA, which is the standard domestic/commercial rating. It's a distribution breaker, not a motor-protective device; the thermal-magnetic trip unit handles overloads and short-circuits in one package.

Snaps onto DIN rail (EN/IEC 60715) and occupies 6 x 9 mm pitches — 54 mm wide for the 3P block. The removable comb busbar installs across the top or bottom terminals, so you can gang-feed multiple breakers in a distribution board without individual bridging. Terminals accept 1–35 mm² rigid or 1–25 mm² flexible, stripped to 14 mm, torqued to 3.5 N·m. IP20 B finger-safe on the front face; suitable for dry indoor enclosures, not washdown.

Marked as current production (L* lifecycle stage). No NRND or phase-out flag. This is the standard Acti9 iT60N — widely specified across European and Middle East distribution boards.

Frequently asked questions

What is A9F68340's breaking capacity at 400 V AC?

Under EN/IEC 60898-1, the Icn is 10 kA at 400 V AC 50/60 Hz. Under EN/IEC 60947-2, the Icu is 10 kA at 380–415 V AC and 6 kA at 440 V AC.

What does the C-curve mean on this breaker?

The magnetic trip threshold is 8 x In ±20%, so for a 40 A breaker the instantaneous trip occurs between 256 A and 384 A. This suits moderate inrush loads like small motors, transformers, and fluorescent lighting — not resistive loads (B-curve) or high-starting-current motors (D-curve).

Where can I buy A9F68340?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ to get a firm line.

MPN
A9F68340