Schneider Electric A9F68403 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F68403 Acti9 iT60 MCB, 3 A, C Curve, 4P

MPNA9F68403
Obsolete

Schneider Electric Acti9 iT60, A9F68403, miniature circuit breaker, 3 A, C curve, 4P, 50 kA breaking capacity at 415 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F68403 — Identification
ParameterValue
Product nameActi9 iT60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F68403 — Ratings
ParameterValue
Rated current (In)3 A
Poles configuration4P
Number of protected poles4
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F68403 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
A9F68403 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeRemovable comb busbar installed
Control typeToggle
Terminal connection typeSingle terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Number of 9 mm pitches8
A9F68403 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 B conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 %
Tropicalisation class2 conforming to EN/IEC 60068-2-78
A9F68403 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F68403 is a 4-pole miniature circuit breaker from the Acti9 iT60 series, rated 3 A with a C-curve trip characteristic. Breaking capacity is the headline: 50 kA Icu at 415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V per EN/IEC 60898-1. The dual standard (60947-2 for industrial, 60898-1 for residential/commercial) gives flexibility: it qualifies for distribution boards under 60898-1 and for industrial switchgear under 60947-2. Limitation class 3 (per 60898-1) means it limits let-through energy enough to protect downstream equipment in most fault scenarios.

Deployment context

Mounts on DIN rail (EN rail) — standard for panel builders. Width is 72 mm, which is 8 x 9 mm pitches (the standard MCB module width). The removable comb busbar is pre-installed, so daisy-chaining phases across multiple breakers in a distribution board is straightforward. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible, with a tightening torque of 2 N·m.

Frequently asked questions

What is A9F68403's breaking capacity at 415 V?

50 kA Icu at 380...415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V per EN/IEC 60898-1.

What is the C curve on the A9F68403?

The C curve means magnetic tripping occurs at 8 x In ±20 %, suitable for inductive loads with moderate inrush like lighting banks or control transformers.

Where can I buy the A9F68403?

The A9F68403 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
A9F68403