Skip to main content
Schneider Electric A9F85204

Schneider A9F85204 iC60H MCB, 2-pole, D-curve, 4 A, 70 kA

MPNA9F85204
Obsolete

Schneider A9F85204 Acti 9 Miniature Circuit Breakers Mcbs — now discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.

$96.70Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F85204 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Product or component typeMiniature circuit-breaker
Voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ue] rated operational voltage12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 125 V DC
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2
Breaking capacity70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Current4 A
[Ics] rated service breaking capacity70 kA 100 % x Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA 100 % x Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA 100 % x Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA 100 % x Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA 100 % x Icu at <= 125 V DC conforming to EN/IEC 60947-2
Network frequency50/60 Hz
Poles description2P
Number of protected poles2

All specifications

A9F85204 additional specifications
ParameterValue
Utilisation categoryCategory A conforming to EN/IEC 60947-2
IP degree of protectionIP20 conforming to IEC 60529 IP40 in modular enclosure (Insulation class II) conforming to IEC 60529
Mounting modeClip-on Removable comb busbar installed
Mounting support35 mm DIN rail
Connection pitch18 mm between phases
Wire stripping length14 mm for top or bottom connection
Connections - terminalsSingle terminal (top or bottom) , for 1 cable(s) , 1...25 mm², rigid, copper Single terminal (top or bottom) , for 1 cable(s) , 1...16 mm², flexible, copper Single terminal (top or bottom) , for 1 cable(s) , 1...16 mm², flexible with ferrule, copper Single terminal (top or bottom) , for 1.0 cable(s) , flexible, copper or aluminium, with ring terminal and accessory
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Operating altitude0...2000 m
Depth78.5 mm
Width36 mm
ColorWhite
Height85 mm
Product weight0.25 kg
Electrical durability10000 cycles
Mechanical durability20000 cycles
StandardsEN/IEC 60947-2 EN/IEC 60898-1
RangeActi9
Curve codeD
9 mm pitches4
Tropicalisation2 conforming to IEC 60068-1
Limitation class3 conforming to EN/IEC 60898-1
Local signallingTrip indicator
Device short nameiC60H
Tightening torque2 N.m top or bottom
Device applicationDistribution
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Contact position indicatorYes
Ambient air temperature for storage-40...85 °C
Ambient air temperature for operation-35...70 °C
Comb busbar and distribution block compatibilityTop or bottom: YES

Product details

Overview

The A9F85204 is a Schneider Acti9 iC60H miniature circuit breaker with 2 poles, a D-curve, and a 4 A switching current. The part is in active production.

Schneider lists the A9F85204 as an active, in-production item. For firm lead time and quantity, submit an RFQ.

Alternatives & selection

Versus the A9F83302 (3-pole, B-curve, 2 A), the A9F85204 uses a D-curve with a magnetic tripping limit of 12 x In ±20% versus 4 x In ±20% on the B-curve peer. The A9F85204 also carries a higher 4 A switching current versus 2 A. A panel specified around the A9F83302 would require rewiring for the 2-pole A9F85204 and a different trip characteristic.

MPN
A9F85204