Schneider Electric A9KR14463BQ — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9KR14463BQ Acti9 ID K RCCB, 63 A, 300 mA

MPNA9KR14463BQ
Active

Schneider Electric Acti9 ID K, A9KR14463BQ, 4P RCCB, 63 A, 300 mA, Type AC, 380-415 V AC, instantaneous, DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9KR14463BQ — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9KR14463BQ — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)380...415 V AC 50 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)440 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemGroup incomer
Electrical durabilityAC-1: 4000 cycles
Mechanical durability (operating cycles)5000 cycles
A9KR14463BQ — Identification
ParameterValue
Product nameActi9 ID K
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameID K
A9KR14463BQ — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsBiconnect top or bottom 1...35 mm² rigid Biconnect top or bottom 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height81 mm
Depth68 mm
A9KR14463BQ — Environmental
ParameterValue
Operating ambient temperature-5...55 °C
Storage ambient temperature-25...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9KR14463BQ — Approvals
ParameterValue
StandardsIS 12640-1 EN/IEC 61008-1 EN/IEC 61008-2-1

Product details

The Schneider Electric A9KR14463BQ is a 4-pole residual current circuit breaker (RCCB) from the Acti9 ID K range, rated at 63 A with 300 mA earth-leakage sensitivity. The 63 A rating and 300 mA sensitivity make it a fit for group incomer duty in a distribution board where you need whole-circuit ground-fault protection rather than individual branch protection.

Mounts on DIN rail via clip-on, and at 72 mm wide (4 modules at 18 mm each) it takes up standard panel space for a 4P device. Terminals accept up to 35 mm² rigid or 25 mm² flexible — enough for 63 A incoming tails — and the tightening torque is 3.5 N.m top or bottom. Strip length is 14 mm. The biconnect terminals let you loop out without an extra bar, which wires up clean in a group incomer position.

Rated breaking and making capacity is Idm 630 A / Im 630 A — that's the short-circuit capacity for this RCCB under the product standard. The device is voltage-independent for residual current tripping, so it doesn't need an external supply to detect a ground fault. Electrical durability is 4000 cycles under AC-1 (resistive load); mechanical durability is 5000 cycles. The IP20 rating on the body (IP40 in a modular enclosure) means it's for dry indoor panels only — no washdown exposure.

Lifecycle stage is marked as current production. The part complies with IS 12640-1, EN/IEC 61008-1, and EN/IEC 61008-2-1 — the Indian and international standards for RCCBs. Storage temperature range is -25 to 85 °C; operating ambient isn't explicitly stated, but the tropicalisation class 2 per IEC 60068-1 suggests it's treated for damp-heat environments up to 95 % RH at 55 °C.

Frequently asked questions

Where can I buy the A9KR14463BQ and get a price?

This RCCB is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What does the 300 mA sensitivity mean for this RCCB?

The 300 mA earth-leakage sensitivity is a high-threshold setting intended for group incomer or main-switch duty, where you want to detect ground faults but avoid nuisance tripping from normal leakage currents of multiple downstream circuits. It is not suitable for personal shock protection — that requires 30 mA or lower.

What standards does the A9KR14463BQ comply with?

It complies with IS 12640-1, EN/IEC 61008-1, and EN/IEC 61008-2-1, covering the requirements for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses.

What is the difference between this Type AC RCCB and a Type A?

This Type AC device detects sinusoidal AC residual currents only. A Type A RCCB additionally detects pulsating DC residual currents, which can be present in circuits with rectifiers, switching power supplies, or variable-speed drives. If your downstream loads include electronics, a Type A would be the correct choice.

MPN
A9KR14463BQ