Schneider Electric A9L08221 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9L08221 Acti9 iPRD8r Surge Arrester, 2P,

MPNA9L08221
Obsolete

Schneider Electric Acti9 iPRD, surge arrester with pluggable cartridge, Type 2 + 3, 2P, IT earthing, 460 V Uc, 8 kA Imax, remote signalling, clip-on DIN rail, white (RAL 9003).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9L08221 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)230 V AC (+/- 10 %) at 50/60 Hz
Poles description2P
A9L08221 — Identification
ParameterValue
Product nameActi9 iPRD
Product / component typeSurge arrester with pluggable cartridge
Device short nameiPRD8r
A9L08221 — Mechanical
ParameterValue
Mounting modeClip-on (DIN rail)
Width in 9 mm modules4
Terminal connectionsTunnel type terminal (downside) 2.5...25 mm² rigid Tunnel type terminal (upside) 2.5...25 mm² rigid Tunnel type terminal (downside) 4...16 mm² flexible Tunnel type terminal (upside) 4...16 mm² flexible
Terminal tightening torque3.5 N.m
Width36 mm
Height70 mm
Depth90 mm
A9L08221 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...80 °C
Relative humidity5...95 %
Operating altitude2000 m
A9L08221 — Approvals
ParameterValue
StandardsEN 61643-11:2012 IEC 61643-11:2011

Product details

Surge protection for IT distribution networks

It is a Type 2 + 3 device, meaning it handles both main distribution board protection (Type 2) and fine protection for sensitive loads (Type 3) in a single unit. Rated for 230 V AC (+/- 10 %) at 50/60 Hz, it provides common-mode protection between line and PE with a maximum continuous operating voltage (Uc) of 460 V L/PE. This 2-pole arrester uses MOV technology and delivers a nominal discharge current (In) of 2.5 kA and a maximum discharge current (Imax) of 8 kA in common mode (L/PE). The voltage protection level (Up) is below 1.8 kV in Type 3 mode, which is sufficient to protect most downstream equipment with a 2.5 kV impulse withstand. The unit includes a remote signalling contact (1 C/O) rated at 0.25 A / 250 V AC for monitoring the arrester status from a PLC or building management system.

The A9L08221 clips onto a standard 35 mm DIN rail and occupies 4 x 9 mm pitches (36 mm width). The housing is white (RAL 9003) and stands 70 mm tall with a depth of 90 mm. Tunnel-type terminals on both top and bottom accept rigid conductors from 2.5 to 25 mm² or flexible conductors from 4 to 16 mm². For IT systems, the arrester must be installed between each live conductor and PE (no N-PE mode). The manufacturer specifies an associated upstream overcurrent protective device: either an iC60L circuit breaker (10 A, curve C, 25 kA Icu) or gG fuses (25 A / 15 kA or 80 A / 50 kA). The short-circuit withstand of the arrester itself is 5 kA at 415 V phase-to-phase.

Environmental and operational limits

Relative humidity range is 5 to 95 %. Maximum operating altitude is 2000 m. The temporary overvoltage (TOV) withstand is 337 V L/N for 5 seconds; in safe failure mode it withstands 1453 V L/PE for 200 ms. Ground residual current (Ipe) is 0.6 mA.

Frequently asked questions

What is the A9L08221 used for?

It is a Type 2 + 3 surge arrester for IT earthing systems (unearthed networks), protecting 230 V AC distribution circuits against lightning and switching surges. It combines main distribution and fine protection in one unit.

What are the key ratings of the A9L08221?

Rated voltage 230 V AC, Uc 460 V L/PE, In 2.5 kA, Imax 8 kA, Up <1.8 kV (Type 3). Short-circuit withstand 5 kA at 415 V. Operating temperature -25 to +60 °C.

How do I get pricing and availability for the A9L08221?

This part is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time.

What compliance standards does the A9L08221 meet?

It complies with EN 61643-11:2012 and IEC 61643-11:2011 for surge protective devices.

MPN
A9L08221