Skip to main content
Schneider Electric A9N21386 — Miniature Circuit Breakers (MCB)

Schneider Electric A9N21386 DT40N MCB, 16 A, 3P, C-Curve, 6

MPNA9N21386
Obsolete

Schneider Electric ProDis DT40N, miniature circuit breaker, 16 A, 3P, C-curve, 6 kA Icn / 10 kA Icu, thermal-magnetic, clip-on DIN rail, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N21386 — Identification
ParameterValue
Product nameDT40
Product rangeProdis
Product range (series)ProDis
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9N21386 — Ratings
ParameterValue
Rated current (In)16 A
Poles configuration3P
Number of protected poles3
Breaking capacity6000 A Icn at 400 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 400...415 V AC 50 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)6000 A 100 % x Icn at 400 V AC 50 Hz conforming to EN/IEC 60898-1 7.5 kA 75 % x Icu at 400 V AC 50 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)400 V AC 50 Hz between phases
Rated insulation voltage (Ui)440 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50 Hz
A9N21386 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit5...10 x In
Earth-leakage protectionSeparate block
Suitability for isolationYes
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)20000 cycles
Mechanical durability (cycles)20000 cycles
A9N21386 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Terminal connection typeTunnel type terminals downstream 0.33...10 mm² flexible Tunnel type terminals downstream 0.75...16 mm² rigid Tunnel type terminals upstream 0.33...10 mm² flexible Tunnel type terminals upstream 0.75...16 mm² rigid
Terminal tightening torque2 N.m
Wire stripping length13 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height81 mm
Depth78 mm
Number of 9 mm pitches6
A9N21386 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9N21386 — Approvals
ParameterValue
StandardsEN/IEC 60898-1 EN/IEC 60947-2

Product details

The breaking capacity is 6 kA Icn at 400 V AC per EN/IEC 60898-1, and 10 kA Icu at 400–415 V AC per IEC 60947-2 — that dual rating means it's certified for both residential/commercial (60898-1) and industrial (60947-2) fault levels, so you can use it in a sub-distribution board feeding a machine line without worrying about the higher prospective fault current. Pollution degree 3 and tropicalisation class 2 (IEC 60068-1) confirm it's suited for humid, dusty environments like a warehouse or food-processing area, not just a clean control room.

The terminals accept 0.33 to 16 mm² rigid or 0.33 to 10 mm² flexible, with a 13 mm strip length and 2 N·m tightening torque. That covers most panel-building wire sizes from 1.5 mm² control wiring up to 10 mm² feeder tails. The 3-pole unit occupies 6 x 9 mm pitches (54 mm wide), so plan for that slot count on your DIN rail. IP20 front-of-panel protection means it's fine inside an enclosure but not for wet washdown areas.

Frequently asked questions

Where can I buy A9N21386 and how do I get a price?

We source and quote it to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ and we'll respond with a firm price and delivery estimate.

What is A9N21386's breaking capacity at 400 V?

The Icn is 6000 A per EN/IEC 60898-1, and the Icu is 10 kA at 400–415 V AC per IEC 60947-2. The dual standard means it's rated for both commercial and industrial fault levels.

What compliance documentation does Schneider provide for A9N21386?

The part carries NF quality label certification and is dual-certified to EN/IEC 60898-1 and EN/IEC 60947-2. It also meets tropicalisation class 2 per IEC 60068-1 and pollution degree 3 per IEC 60947-2. RoHS/REACH declarations are standard from the manufacturer.

MPN
A9N21386