Skip to main content
Schneider Electric A9N21415 — Miniature Circuit Breakers (MCB)

Schneider Electric A9N21415 DT40N MCB, 10 A, Curve D, 3P+N,

MPNA9N21415
Obsolete

Schneider Electric ProDis DT40N miniature circuit breaker, A9N21415, 10 A rated, D-curve, 3P+N, 6 kA Icn / 10 kA Icu, dual-standard EN/IEC 60898-1 & 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N21415 — Identification
ParameterValue
Product nameDT40
Product rangeProdis
Product range (series)ProDis
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9N21415 — Ratings
ParameterValue
Rated current (In)10 A
Poles configuration3P + N
Number of protected poles3
Breaking capacity6000 A Icn at 400 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 400...415 V AC 50 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)6000 A 100 % x Icn at 400 V AC 50 Hz conforming to EN/IEC 60898-1 7.5 kA 75 % x Icu at 400 V AC 50 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)230 V AC 50 Hz between phase and neutral 400 V AC 50 Hz between phases
Rated insulation voltage (Ui)400 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50 Hz
A9N21415 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit10...14 x In
Earth-leakage protectionSeparate block
Suitability for isolationYes
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)20000 cycles
Mechanical durability (cycles)20000 cycles
A9N21415 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Terminal connection typeTunnel type terminals downstream 0.33...10 mm² flexible Tunnel type terminals downstream 0.75...16 mm² rigid Tunnel type terminals upstream 0.33...10 mm² flexible Tunnel type terminals upstream 0.75...16 mm² rigid
Terminal tightening torque2 N.m
Wire stripping length13 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height81 mm
Depth78 mm
Number of 9 mm pitches6
A9N21415 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9N21415 — Approvals
ParameterValue
StandardsEN/IEC 60898-1 EN/IEC 60947-2

Product details

The Schneider Electric A9N21415 is a DT40N miniature circuit breaker from the ProDis range, rated 10 A with a D-curve magnetic trip of 10...14 x In. That trip band is sized for loads with high inrush — think motor starters, small transformers, or capacitor banks — where a B- or C-curve would nuisance-trip on startup. The 3P+N configuration (three protected poles plus a switched neutral) suits three-phase distribution panels where the neutral needs to be disconnected with the phases. Breaking capacity is dual-rated: 6 kA Icn at 400 V AC per EN/IEC 60898-1 for general distribution, and 10 kA Icu at 400...415 V AC per IEC 60947-2 for industrial circuits with higher fault current. IP20 finger-safe terminals — standard for panel-mount, not for wet environments.

It carries dual certification to EN/IEC 60898-1 and IEC 60947-2, plus NF quality label and tropicalisation class 2 per IEC 60068-1 (95 % RH at 55 °C). That dual standard is useful: the 60898-1 rating covers domestic/commercial distribution, while the 60947-2 rating satisfies industrial panel requirements — one part, two compliance boxes.

Integration and deployment

The 54 mm width (6 modules) occupies six 9 mm pitches in the enclosure — plan your rail fill accordingly. Neutral is on the left, which matches typical European panel layout conventions. Earth-leakage protection requires a separate block (not integrated). If you need RCD functionality, you'll add a downstream or companion residual-current device. The thermal-magnetic trip unit handles overload and short-circuit only.

Frequently asked questions

What is the breaking capacity of A9N21415?

6 kA Icn at 400 V AC per EN/IEC 60898-1, and 10 kA Icu at 400...415 V AC per IEC 60947-2.

What is the D-curve trip range on this MCB?

Magnetic tripping occurs at 10...14 x In (100...140 A for the 10 A rating), designed for loads with high inrush current.

Where can I buy A9N21415?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
A9N21415