Skip to main content
Schneider Electric A9N21420 — Miniature Circuit Breakers (MCB)

Schneider Electric A9N21420 DT40N MCB, D Curve 40 A 3P+N, 6

MPNA9N21420
Obsolete

Schneider Electric ProDis DT40N, miniature circuit breaker, D curve, 40 A, 3P+N, 6 kA Icn / 10 kA Icu, clip-on DIN rail mount, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N21420 — Identification
ParameterValue
Product nameDT40
Product rangeProdis
Product range (series)ProDis
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9N21420 — Ratings
ParameterValue
Rated current (In)40 A
Poles configuration3P + N
Number of protected poles3
Breaking capacity6000 A Icn at 400 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 400...415 V AC 50 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)6000 A 100 % x Icn at 400 V AC 50 Hz conforming to EN/IEC 60898-1 7.5 kA 75 % x Icu at 400 V AC 50 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)230 V AC 50 Hz between phase and neutral 400 V AC 50 Hz between phases
Rated insulation voltage (Ui)400 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50 Hz
A9N21420 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit10...14 x In
Earth-leakage protectionSeparate block
Suitability for isolationYes
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9N21420 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Terminal connection typeTunnel type terminals downstream 0.33...10 mm² flexible Tunnel type terminals downstream 0.75...16 mm² rigid Tunnel type terminals upstream 0.33...10 mm² flexible Tunnel type terminals upstream 0.75...16 mm² rigid
Terminal tightening torque2 N.m
Wire stripping length13 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height81 mm
Depth78 mm
Number of 9 mm pitches6
A9N21420 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9N21420 — Approvals
ParameterValue
StandardsEN/IEC 60898-1 EN/IEC 60947-2

Product details

Breaking capacity is dual-rated: 6 kA Icn per EN/IEC 60898-1 for general distribution, and 10 kA Icu per IEC 60947-2 for industrial panel duty. Clip-on mounting to DIN rail, 54 mm wide (6 x 9 mm pitches), with tunnel terminals accepting up to 16 mm² rigid or 10 mm² flexible on both line and load sides. IP20 finger-safe front; the 78 mm depth leaves clearance behind a standard 100 mm deep enclosure gland plate.

Dual-standard certification and deployment context

Rated to both EN/IEC 60898-1 (household / similar installation MCB standard) and EN/IEC 60947-2 (industrial low-voltage switchgear standard). This dual rating is the key spec for a panel builder: the 60898-1 side covers the branch circuit protection for a fixed load, while the 60947-2 side covers the isolation and fault-breaking duty inside an industrial enclosure. The 2000 m operating altitude covers most industrial sites; above that, dielectric strength derates per the standard.

D curve selection — what it means for the buyer

The D curve (10–14 x In magnetic trip) is the deciding factor for fit. A 40 A D-curve MCB will pass the starting current of a 15 kW direct-on-line motor (typically 6–8 x FLA for 5–10 seconds) without tripping, where a C curve (5–10 x In) might nuisance-trip on a hard-starting load.

Frequently asked questions

What standards does the A9N21420 comply with?

Dual-rated to EN/IEC 60898-1 and EN/IEC 60947-2, with pollution degree 3 and tropicalisation level 2 per IEC 60068-1.

MPN
A9N21420