Skip to main content
Schneider Electric A9N3P01CIN — Miniature Circuit Breakers (MCB)

Schneider Electric A9N3P01CIN Acti9 xC60 MCB, 1 A C-Curve 3P

MPNA9N3P01CIN
Active

Schneider Electric Acti9 xC60, A9N3P01CIN, miniature circuit breaker, 3P, 1 A, C-curve, 10 kA breaking capacity at 400 V AC, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N3P01CIN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Product range (series)Acti9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9N3P01CIN — Ratings
ParameterValue
Rated current (In)1 A
Poles configuration3P
Number of protected poles3
Breaking capacity10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2
Rated service breaking capacity (Ics)7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA conforming to IS/IEC 60947-2 - 100...125 V DC
Rated operational voltage (Ue)220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Rated impulse withstand voltage (Uimp)4 kV conforming to IS/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to IS/IEC 60947-2
Overvoltage categoryIV
A9N3P01CIN — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to IS/IEC 60947-2
Limitation class3 conforming to IS/IEC 60947-2
Electrical durability (cycles)20000 cycles
Mechanical durability (cycles)20000 cycles
A9N3P01CIN — Mechanical
ParameterValue
Mounting support35 mm DIN rail
Mounting modeClip-on
Control typeToggle
Terminal connection typeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Wire stripping length13 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height85 mm
Depth77.5 mm
Number of 9 mm pitches6
A9N3P01CIN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9N3P01CIN — Approvals
ParameterValue
StandardsIS/IEC 60947-2

Product details

The Schneider Electric A9N3P01CIN is an Acti9 xC60 miniature circuit breaker — three-pole, rated 1 A, C-curve, with a 10 kA breaking capacity at 380–415 V AC (IS/IEC 60947-2).

DIN-rail fit and panel integration

The 54 mm width takes six 9 mm pitches — a standard 3-module footprint for a three-pole MCB. Depth is 77.5 mm, height 85 mm. IP20 finger-safe terminals — fine inside an enclosure, not for wet locations.

Rated current 1 A — sized for a small lighting circuit, a control transformer primary, or a signal-conditioning loop. Thermal-magnetic trip unit gives time-delayed thermal protection against sustained overloads and instantaneous magnetic protection against short circuits. Suitability for isolation means you can use it as a local disconnect with a visible ON/OFF indicator.

Frequently asked questions

What is the breaking capacity of A9N3P01CIN?

The A9N3P01CIN has a 10 kA Inc breaking capacity at 380–415 V AC (IS/IEC 60947-2) and a 15 kA Icu at 100–125 V DC.

Where can I buy A9N3P01CIN?

The A9N3P01CIN is sourced and quoted to order against an RFQ through independent distribution channels; availability and current pricing are confirmed at quote time.

MPN
A9N3P01CIN