Skip to main content
Schneider Electric A9N3P02CIN — Miniature Circuit Breakers (MCB)

A9N3P02CIN Acti9 xC60 MCB, 3P C-curve, 2 A, 10 kA

MPNA9N3P02CIN
Active

Schneider Electric Acti9 xC60 miniature circuit-breaker, 3P, C-curve, 2 A, breaking capacity 10 kA at 380–415 V AC, 15 kA at 100–125 V DC, clip-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N3P02CIN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Product range (series)Acti9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9N3P02CIN — Ratings
ParameterValue
Rated current (In)2 A
Poles configuration3P
Number of protected poles3
Breaking capacity10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2
Rated service breaking capacity (Ics)7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA conforming to IS/IEC 60947-2 - 100...125 V DC
Rated operational voltage (Ue)220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Rated impulse withstand voltage (Uimp)4 kV conforming to IS/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to IS/IEC 60947-2
Overvoltage categoryIV
A9N3P02CIN — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to IS/IEC 60947-2
Limitation class3 conforming to IS/IEC 60947-2
Electrical durability (cycles)20000 cycles
Mechanical durability (cycles)20000 cycles
A9N3P02CIN — Mechanical
ParameterValue
Mounting support35 mm DIN rail
Mounting modeClip-on
Control typeToggle
Terminal connection typeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Wire stripping length13 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height85 mm
Depth77.5 mm
Number of 9 mm pitches6
A9N3P02CIN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9N3P02CIN — Approvals
ParameterValue
StandardsIS/IEC 60947-2

Product details

It protects downstream wiring and loads against overloads and short-circuits, and meets IS/IEC 60947-2 for distribution applications. Breaking capacity is 10 kA at 380–415 V AC 50/60 Hz and 15 kA at 100–125 V DC, both per IS/IEC 60947-2. The C-curve magnetic trip is set at 8 x In ±20 %, so it holds through moderate inrush (typical of small motors or lighting ballasts) but trips fast on hard shorts. Rated current is 2 A, so it's sized for a 2 A branch circuit — not for motor feeders or high-load panels. Clip-on mounting to a 35 mm DIN rail, 54 mm wide (6 x 9 mm pitches), 85 mm tall, 77.5 mm deep. IP20 finger-safe terminals. Pollution degree 3, overvoltage category IV — rated for main panel installation, not just sub-distribution.

Wire strip length is 13 mm. Tightening torque 2 N.m. Earth-leakage protection requires a separate block — not built-in.

Frequently asked questions

What is the breaking capacity of the A9N3P02CIN?

10 kA at 380–415 V AC 50/60 Hz and 15 kA at 100–125 V DC, both per IS/IEC 60947-2.

MPN
A9N3P02CIN