Skip to main content
Schneider Electric A9N3P10BGN — Miniature Circuit Breakers (MCB)

Schneider Electric A9N3P10BGN Acti9 xC60 MCB, 10A, B Curve,

MPNA9N3P10BGN
Active

Schneider Electric Acti9 xC60, miniature circuit breaker, A9N3P10BGN, 10 A, B curve, 3P, 10 kA Icn, clip-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N3P10BGN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Product range (series)Acti9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9N3P10BGN — Ratings
ParameterValue
Rated current (In)10 A
Poles configuration3P
Number of protected poles3
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Rated operational voltage (Ue)220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
A9N3P10BGN — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit3...5 x In
Earth-leakage protectionSeparate block
Limitation class3 conforming to IS/IEC 60898-1
Electrical durability (cycles)20000 cycles
Mechanical durability (cycles)20000 cycles
A9N3P10BGN — Mechanical
ParameterValue
Mounting support35 mm DIN rail
Mounting modeClip-on
Control typeToggle
Terminal connection typeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Wire stripping length13 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height85 mm
Depth77.5 mm
Number of 9 mm pitches6
A9N3P10BGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9N3P10BGN — Approvals
ParameterValue
StandardsIS/IEC 60898-1

Product details

The Schneider Electric A9N3P10BGN is an Acti9 xC60 miniature circuit breaker — a thermal-magnetic MCB rated 10 A, B-curve, 3-pole, designed for distribution boards on 35 mm DIN rail. It clips onto the rail and occupies 6 x 9 mm pitches (54 mm wide). The 10 kA Icn at 240 V and 415 V AC (per IS/IEC 60898-1) covers most commercial and light industrial fault levels; the limitation class 3 rating means it limits let-through energy well enough to coordinate with downstream equipment.

Rated current 10 A is the continuous load it carries at 30 °C ambient without tripping. The thermal-magnetic trip unit responds to sustained overloads (thermal bimetal) and short-circuits (solenoid). Magnetic tripping between 3 and 5 x In means the breaker holds motor inrush from small contactor coils and power supplies but clears a hard fault fast. Breaking capacity 10,000 A Icn at both 240 V and 415 V AC — that is the maximum prospective fault current it can interrupt without welding or exploding. For most distribution panels fed from a 200 kVA transformer or smaller, that is adequate headroom. The rated operational voltage covers 220–240 V and 380–415 V AC, 50/60 Hz, so it works on single-phase and three-phase networks within those bands.

Integration notes

IP20 finger-safe front, pollution degree 3 (conductive pollution expected in industrial enclosures). The white housing with toggle ON/OFF indication is standard for Acti9 panels.

Frequently asked questions

How do I get pricing and availability for A9N3P10BGN?

This part is sourced to order against an RFQ through our independent distribution channel. Submit a request and we will confirm current pricing and availability at quote time.

What is the breaking capacity of A9N3P10BGN?

It is rated 10,000 A Icn at both 240 V AC and 415 V AC, 50/60 Hz, conforming to IS/IEC 60898-1.

What compliance documentation is available for A9N3P10BGN?

The breaker is certified to IS/IEC 60898-1 and carries tropicalisation class 2 per IEC 60068-1. For specific RoHS, REACH, or UL declarations, the manufacturer provides compliance documentation upon request.

MPN