Skip to main content
Schneider Electric A9N3P16DIN — Miniature Circuit Breakers (MCB)

Schneider Electric A9N3P16DIN Acti9 xC60 MCB, 16 A D Curve,

MPNA9N3P16DIN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N3P16DIN, 3-pole, 16 A rated current, D tripping curve, 10 kA breaking capacity at 415 V AC, clip-on 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N3P16DIN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Product range (series)Acti9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9N3P16DIN — Ratings
ParameterValue
Rated current (In)16 A
Poles configuration3P
Number of protected poles3
Breaking capacity10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2
Rated service breaking capacity (Ics)7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA conforming to IS/IEC 60947-2 - 100...125 V DC
Rated operational voltage (Ue)220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Rated impulse withstand voltage (Uimp)4 kV conforming to IS/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to IS/IEC 60947-2
Overvoltage categoryIV
A9N3P16DIN — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to IS/IEC 60947-2
Limitation class3 conforming to IS/IEC 60947-2
Electrical durability (cycles)20000 cycles
Mechanical durability (cycles)20000 cycles
A9N3P16DIN — Mechanical
ParameterValue
Mounting support35 mm DIN rail
Mounting modeClip-on
Control typeToggle
Terminal connection typeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Wire stripping length13 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height85 mm
Depth77.5 mm
Number of 9 mm pitches6
A9N3P16DIN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9N3P16DIN — Approvals
ParameterValue
StandardsIS/IEC 60947-2

Product details

The Schneider Electric A9N3P16DIN is a 3-pole miniature circuit breaker from the Acti9 xC60 range, rated at 16 A with a D tripping curve. The 10 kA breaking capacity at 380–415 V AC (IS/IEC 60947-2) tells you it can safely interrupt a fault current up to that level on a 400 V distribution bus. At 100–125 V DC the Icu rises to 15 kA, which covers DC auxiliary circuits in the same panel. Thermal-magnetic trip technology, Category A utilisation (no intentional short-time delay), and suitability for isolation per IS/IEC 60947-2. Pollution degree 3 means it handles the conductive dust and humidity you find in industrial panels, not just clean indoor switchgear.

The biconnect feature on the bottom terminals lets you daisy-chain a second conductor without a separate terminal block, saving a row on the rail. IP20 finger-safe front, so it is fine inside a locked cabinet but not for washdown zones. Earth-leakage protection is handled by a separate block (not integrated), so if the spec calls for RCD protection, you need an adjacent vigi module on the rail. The ON/OFF toggle gives local visual indication — no auxiliary contact built in, but add one if you need remote status for a PLC input.

Frequently asked questions

What is the breaking capacity of A9N3P16DIN?

10 kA Icn at 380–415 V AC 50/60 Hz per IS/IEC 60947-2, and 15 kA Icu at 100–125 V DC.

Where can I buy A9N3P16DIN?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest alternative to A9N3P16DIN in the Acti9 family?

Within the same xC60 series, the main variant choice is the tripping curve — the C-curve version (A9N3P16C) trips at 5–10 x In instead of the D-curve's 10–14 x In. For motor and transformer loads with high inrush, the D curve is the correct pick; the C curve would nuisance-trip on the same surge.

MPN