Skip to main content
Schneider Electric A9N3P32CGN — Miniature Circuit Breakers (MCB)

Schneider Electric A9N3P32CGN Acti9 xC60 MCB, 32A, 3P, C-Cur

MPNA9N3P32CGN
Active

Schneider Electric Acti9 xC60 series, miniature circuit breaker, 32 A, 3P, C-curve, 10 kA Icn at 240/415 V AC, clip-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N3P32CGN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Product range (series)Acti9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9N3P32CGN — Ratings
ParameterValue
Rated current (In)32 A
Poles configuration3P
Number of protected poles3
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Rated operational voltage (Ue)220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
A9N3P32CGN — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit5...10 x In
Earth-leakage protectionSeparate block
Limitation class3 conforming to IS/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9N3P32CGN — Mechanical
ParameterValue
Mounting support35 mm DIN rail
Mounting modeClip-on
Control typeToggle
Terminal connection typeBiconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid
Terminal tightening torque3.5 N.m
Wire stripping length13 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height85 mm
Depth77.5 mm
Number of 9 mm pitches6
A9N3P32CGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9N3P32CGN — Approvals
ParameterValue
StandardsIS/IEC 60898-1

Product details

What it is and what it does

The Schneider Electric A9N3P32CGN is an Acti9 xC60 miniature circuit breaker — a thermal-magnetic MCB for AC distribution in commercial and light industrial panels. Rated 32 A on a 3-pole (3P) body, it clips onto a 35 mm DIN rail and occupies 6 x 9 mm pitches (54 mm wide). The C-curve trips magnetically between 5 and 10 times rated current — the standard choice for mixed resistive and moderate inductive loads (lighting, small motors, general socket circuits) where inrush is higher than a B-curve allows but lower than a D-curve needs. Breaking capacity is 10 kA Icn at both 240 V and 415 V AC, certified to IS/IEC 60898-1. That means it can safely interrupt a fault up to 10 kA without welding contacts or rupturing the case — sufficient for most secondary distribution boards fed by a transformer with typical source impedance.

Integration and panel fit

Clip-on mounting on a 35 mm DIN rail — standard for any IEC enclosure. The 54 mm width (3P) and 77.5 mm depth fit alongside other Acti9 devices without spacing issues. Terminals accept up to 35 mm² rigid or 25 mm² flexible; the biconnect bottom terminal allows daisy-chaining busbars or outgoing cables. Tightening torque is 3.5 N·m. Rated operational voltage covers 220–240 V and 380–415 V AC, 50/60 Hz — single-phase or three-phase networks. Pollution degree 3 and overvoltage category IV suit it for main panel incoming positions, not just sub-distribution. IP20 finger-safe terminals; the toggle provides ON/OFF indication. Tropicalisation class 2 per IEC 60068-1 means it handles 95 % RH at 55 °C — fine for unventilated enclosures in humid environments.

Frequently asked questions

What standard does the A9N3P32CGN comply with?

It is certified to IS/IEC 60898-1, the Indian/IEC standard for miniature circuit breakers in household and similar installations.

What is the closest alternative to the A9N3P32CGN in the same family?

Within the Acti9 xC60 range, the closest peer is a 32 A, 3P, C-curve MCB with the same breaking capacity and form factor. The deciding factor between variants is typically the curve code (B, C, or D) and the number of poles — this part is the standard C-curve 3-pole version for general distribution.

MPN
A9N3P32CGN