Specifications

A9N4P16CGN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Product range (series)Acti9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9N4P16CGN — Ratings
ParameterValue
Rated current (In)16 A
Poles configuration4P
Number of protected poles4
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Rated operational voltage (Ue)220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
A9N4P16CGN — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit5...10 x In
Earth-leakage protectionSeparate block
Limitation class3 conforming to IS/IEC 60898-1
Electrical durability (cycles)20000 cycles
Mechanical durability (cycles)20000 cycles
A9N4P16CGN — Mechanical
ParameterValue
Mounting support35 mm DIN rail
Mounting modeClip-on
Control typeToggle
Terminal connection typeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Wire stripping length13 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width72 mm
Height85 mm
Depth77.5 mm
Number of 9 mm pitches8
A9N4P16CGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9N4P16CGN — Approvals
ParameterValue
StandardsIS/IEC 60898-1

Product details

It protects downstream wiring and loads against overloads and short circuits using a thermal-magnetic trip mechanism. Four protected poles (4P) let it switch all live conductors in a single-phase or three-phase system, giving full isolation when the toggle is OFF. The ON/OFF indicator on the front confirms contact position at a glance.

Breaking capacity is 10 kA Icn at both 240 V and 415 V AC, certified to IS/IEC 60898-1. Limitation class 3 per the same standard means it limits let-through energy enough to protect downstream equipment during a short circuit. Pair it with a properly rated upstream device and you get Type 2 coordination for contactors and drives.

At 72 mm wide (8 x 9 mm pitches) it occupies four modular slots, which is expected for a 4P breaker. Tropicalisation level 2 per IEC 60068-1 means it's treated against humidity and fungal growth — a plus for installations in coastal or high-humidity regions.

Frequently asked questions

What are the key ratings of the A9N4P16CGN?

Rated current 16 A, C-curve, 4 poles, breaking capacity 10 kA at 240/415 V AC per IS/IEC 60898-1.

What is the closest alternative to A9N4P16CGN in the Acti9 family?

Within the Acti9 xC60 range, the closest peer is the same 16 A C-curve 4P MCB with identical breaking capacity and dimensions — the difference is typically in the order code suffix for packaging or regional variants. No pin-compatible drop-in from a different manufacturer exists; this is a proprietary Schneider profile.

How do I get current pricing and availability for A9N4P16CGN?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time — we source through independent distribution and can provide a firm quote on request.

What compliance documentation does Schneider provide for A9N4P16CGN?

The breaker is certified to IS/IEC 60898-1 and carries tropicalisation treatment per IEC 60068-1. For RoHS, REACH, and CE declarations, Schneider provides compliance documentation on request — contact us with your PO for the specific certificate package.

MPN
A9N4P16CGN