Schneider Electric A9N4P16CIN — Miniature Circuit Breakers (MCB)

Schneider Electric A9N4P16CIN Acti9 MCB, 16 A, 4P, C Curve,

MPNA9N4P16CIN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N4P16CIN, 16 A, 4 poles, C curve, 10 kA breaking capacity at 415 V AC, clip-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N4P16CIN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Product range (series)Acti9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9N4P16CIN — Ratings
ParameterValue
Rated current (In)16 A
Poles configuration4P
Number of protected poles4
Breaking capacity10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 6 kA Icu at 220...250 V DC conforming to IS/IEC 60947-2
Rated service breaking capacity (Ics)7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz 6 kA conforming to IS/IEC 60947-2 - 220...250 V DC
Rated operational voltage (Ue)220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 220...250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Rated impulse withstand voltage (Uimp)4 kV conforming to IS/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to IS/IEC 60947-2
Overvoltage categoryIV
A9N4P16CIN — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to IS/IEC 60947-2
Limitation class3 conforming to IS/IEC 60947-2
Electrical durability (cycles)20000 cycles
Mechanical durability (cycles)20000 cycles
A9N4P16CIN — Mechanical
ParameterValue
Mounting support35 mm DIN rail
Mounting modeClip-on
Control typeToggle
Terminal connection typeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Wire stripping length13 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width72 mm
Height85 mm
Depth77.5 mm
Number of 9 mm pitches8
A9N4P16CIN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9N4P16CIN — Approvals
ParameterValue
StandardsIS/IEC 60947-2

Product details

For a 16 A feeder in a commercial or light industrial panel, that gives you enough headroom to coordinate with a 25 kA upstream device.

The C curve means magnetic trip occurs at 8 x In ±20 % — so the breaker holds through motor inrush and capacitor charging currents that would nuisance-trip a B curve, but still clears fast on a hard short. For a 16 A circuit, that's a magnetic threshold around 128 A to 154 A. Thermal-magnetic trip unit gives you the standard bimetal overload protection plus the solenoid for short-circuit. No electronic adjustment — set it and forget it, which is exactly what you want in a distribution board where the load is fixed. That's a real differentiator if your site has variable power quality.

Mounts via clip-on to 35 mm DIN rail. Takes 8 x 9 mm pitches. Width 72 mm, height 85 mm, depth 77.5 mm. Wire strip length is 13 mm. Tightening torque 2 N·m — a standard screwdriver setting, no special tooling. Keep it inside the panel. Earth-leakage protection is handled by a separate block, so this is the MCB only; pair it with an RCCB if you need residual current protection.

Frequently asked questions

What is the breaking capacity of A9N4P16CIN?

10 kA at 380–415 V AC, 50/60 Hz, per IS/IEC 60947-2. At 220–250 V DC it's 6 kA Icu.