Skip to main content
Schneider Electric A9N4P32BIN — Miniature Circuit Breakers (MCB)

Schneider Electric A9N4P32BIN Acti9 xC60 MCB, 32 A, 4P, B-Cu

MPNA9N4P32BIN
Active

Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N4P32BIN, 4-pole, B-curve, 32 A rated, 10 kA breaking capacity at 415 V AC, clip-on 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N4P32BIN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Product range (series)Acti9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9N4P32BIN — Ratings
ParameterValue
Rated current (In)32 A
Poles configuration4P
Number of protected poles4
Breaking capacity10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 6 kA Icu at 220...250 V DC conforming to IS/IEC 60947-2
Rated service breaking capacity (Ics)7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz 6 kA conforming to IS/IEC 60947-2 - 220...250 V DC
Rated operational voltage (Ue)220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 220...250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Rated impulse withstand voltage (Uimp)4 kV conforming to IS/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to IS/IEC 60947-2
Overvoltage categoryIV
A9N4P32BIN — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to IS/IEC 60947-2
Limitation class3 conforming to IS/IEC 60947-2
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9N4P32BIN — Mechanical
ParameterValue
Mounting support35 mm DIN rail
Mounting modeClip-on
Control typeToggle
Terminal connection typeBiconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid
Terminal tightening torque3.5 N.m
Wire stripping length13 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width72 mm
Height85 mm
Depth77.5 mm
Number of 9 mm pitches8
A9N4P32BIN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9N4P32BIN — Approvals
ParameterValue
StandardsIS/IEC 60947-2

Product details

The Schneider Electric A9N4P32BIN is a 4-pole miniature circuit-breaker from the Acti9 xC60 range, rated 32 A with a B-curve trip characteristic. The thermal-magnetic trip unit provides overcurrent and short-circuit protection for distribution circuits per IS/IEC 60947-2, utilisation category A. Breaking capacity is 10 kA Icn at 380–415 V AC, 50/60 Hz, and 6 kA Icu at 220–250 V DC — sufficient for most commercial and light industrial panelboards where the upstream fault level is within these limits. The B-curve (magnetic trip at 4 x In ±20%) suits resistive and general-purpose loads where nuisance tripping from inrush is not a concern.

The device is suitable for isolation per the standard, and earth-leakage protection requires a separate block — not integrated. IP20 finger protection is provided for the front face; the terminals are accessible only with the panel door closed.

The 4-pole body measures 85 mm high, 72 mm wide, and 77.5 mm deep — account for the toggle throw and cable bending radius when sizing the enclosure depth. The toggle provides local ON/OFF indication. For a 4-pole breaker at 32 A, derating per the manufacturer's thermal curve should be applied when the ambient temperature exceeds 40 °C or when multiple breakers are ganged without spacing — the 10,000-cycle electrical endurance and 20,000-cycle mechanical endurance assume standard installation conditions.

Sourcing posture

For volume purchases or framework agreements, the part's current lifecycle status and broad compliance (IS/IEC 60947-2, pollution degree 3, overvoltage category IV) support straightforward specification into new or replacement distribution boards.

Frequently asked questions

Who supplies A9N4P32BIN and how is it quoted for volume purchases?

The A9N4P32BIN is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is A9N4P32BIN's listed depth?

The A9N4P32BIN has a listed depth of 77.5 mm.

What is A9N4P32BIN's listed range?

The A9N4P32BIN belongs to the Acti9 range of miniature circuit-breakers.

What compliance documentation does this brand provide for A9N4P32BIN?

The A9N4P32BIN is certified compliant with IS/IEC 60947-2, with pollution degree 3, overvoltage category IV, and tropicalisation class 2 per IEC 60068-1. It is suitable for isolation per the standard.

MPN
A9N4P32BIN