Skip to main content
Schneider Electric A9R11491S — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R11491S Acti9 iID RCCB, 100 A, 30 mA, 4

MPNA9R11491S
Active

Schneider Electric Acti9 iID A9R11491S, 4P residual current circuit breaker (RCCB), 100 A, 30 mA sensitivity, Type AC, 380-415 V AC, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R11491S — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R11491S — Electrical Ratings
ParameterValue
Rated current (In)100 A
Rated operational voltage (Ue)380...415 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R11491S — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R11491S — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height91 mm
Depth73.5 mm
A9R11491S — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R11491S — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN/IEC 61008-2-1

Product details

The Schneider Electric A9R11491S is an Acti9 iID 4-pole residual current circuit breaker (RCCB) rated at 100 A with 30 mA earth-leakage sensitivity. The 30 mA threshold covers personnel protection (indirect contact) per IEC 61008, while the 100 A rating handles the full load current of a distribution outgoer. Clips onto DIN rail, neutral on the left, and the toggle gives a clear visual contact-position indicator.

The 380-415 V AC 50/60 Hz operational voltage covers standard three-phase European and many Asian distribution voltages. The 6 kV impulse withstand and pollution degree 3 qualify it for industrial panels where transient overvoltages and conductive dust are present. The 30 mA sensitivity means it will trip on leakage currents above that threshold — fast enough for personnel protection but not so sensitive that nuisance tripping from normal cable capacitance becomes a problem on a properly wired circuit. The voltage-independent tripping technology means it doesn't need a separate power supply to detect leakage; it uses the fault current itself, so it works even if the neutral is lost upstream.

The 72 mm width occupies 8 modules of 9 mm pitch on the DIN rail. The 73.5 mm depth and 91 mm height are standard for the Acti9 range, so it fits alongside MCBs and other modular devices in a distribution board. Terminals accept 1-35 mm² rigid or 1-25 mm² flexible; strip 14 mm and torque to 3.5 N·m. IP20 body, IP40 within a modular enclosure — fine for indoor panel use. The padlocking option allows lockout/tagout for safe isolation during maintenance.

Frequently asked questions

Where can I buy A9R11491S and get current pricing?

The A9R11491S is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time check.

What is the closest alternative to A9R11491S in the Acti9 family?

Within the Acti9 iID range, the closest alternatives differ by rated current (e.g., 63 A or 40 A versions) or by sensitivity (e.g., 100 mA or 300 mA for fire protection rather than personnel). The 100 A, 30 mA, 4P, Type AC configuration is specific to this order code; a lower-current variant would not carry the same load.

What is A9R11491S's listed depth?

The A9R11491S has a depth of 73.5 mm, which is standard for the Acti9 modular range and fits within typical distribution board enclosures.

What compliance documentation does Schneider provide for A9R11491S?

The A9R11491S is certified to EN/IEC 61008-1 and EN/IEC 61008-2-1, the standards for residual current operated circuit breakers. It carries IP20 and IP40 protection ratings per IEC 60529. For RoHS, REACH, and UL documentation, request the specific compliance pack at RFQ time — these are typically available per batch or per shipment.

MPN