Skip to main content
Schneider Electric A9R22291 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R22291 Acti9 iID RCCB, 100 A, 30 mA, Ty

MPNA9R22291
Active

Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), 2P, 100 A, 100 mA sensitivity, Type A, 230/240 V AC, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9R22291 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R22291 — Electrical Ratings
ParameterValue
Rated current (In)100 A
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R22291 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R22291 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height96 mm
Depth69 mm
A9R22291 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R22291 — Approvals
ParameterValue
StandardsIEC 61008-2-1 AS/NZS 61008.1

Product details

The Schneider Electric A9R22291 is an Acti9 iID residual current circuit breaker (RCCB) — a voltage-independent, instantaneous-trip device sized for 100 A at 230/240 V AC, 50/60 Hz, with 100 mA earth-leakage sensitivity and Type A protection class. The 100 mA sensitivity means it is specified for circuits where a lower 30 mA threshold would cause nuisance tripping from leakage in long cable runs or equipment with natural earth-leakage current — common in sub-distribution, industrial socket-outlet circuits, or fixed equipment. Type A detection covers sinusoidal AC and pulsating DC residual currents up to 100 mA, which covers most modern electronic loads with half-wave rectification.

Integration & termination

Mounts on DIN rail via clip-on mechanism. Terminals accept 1–35 mm² rigid or 1–25 mm² flexible conductors top or bottom; strip length 14 mm, tightening torque 3.5 N.m. IP20 body, IP40 inside a modular enclosure — standard for distribution board installation, not washdown. Locking provision via padlocking device. Dimensions: 36 mm wide, 96 mm high, 69 mm deep, with 44 mm embedding depth behind the panel.

Electrical ratings & standards

Rated insulation voltage 500 V AC; operational voltage 230/240 V AC. Breaking and making capacity: Idm 1500 A, Im 1500 A. Electrical durability 15,000 cycles (AC-1), mechanical durability 20,000 cycles. Pollution degree 3. Withstands 8/20 µs impulse current of 250 A per EN/IEC 61008-1. Storage temperature range -40 to 85 °C. Complies with IEC 61008-2-1 and AS/NZS 61008.1.

Frequently asked questions

Where can I buy A9R22291 and how do I get a price?

The A9R22291 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is A9R22291's listed depth (69 mm) on this component line?

The A9R22291 has a depth of 69 mm, with an embedding depth of 44 mm behind the panel face.

What is A9R22291's listed range (Acti9) on this component line?

The A9R22291 belongs to the Schneider Acti9 range, specifically the iID series of residual current circuit breakers.

What compliance documentation does this brand provide for A9R22291 (RoHS, REACH, UL, IEC)?

The A9R22291 carries RCM and VDE quality labels and complies with IEC 61008-2-1 and AS/NZS 61008.1 standards. The evidence does not list RoHS, REACH, or UL documentation specifically for this order code.

MPN
A9R22291