Schneider Electric A9R82291 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R82291 Acti9 iID RCCB, 100 A, 300 mA, 2

MPNA9R82291
Obsolete

Schneider Electric Acti9 iID RCCB, A9R82291, 2P, 100 A, 300 mA, Type AC, voltage-independent, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R82291 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R82291 — Electrical Ratings
ParameterValue
Rated current (In)100 A
Rated operational voltage (Ue)230...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R82291 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R82291 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height96 mm
Depth74.5 mm
A9R82291 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R82291 — Approvals
ParameterValue
StandardsGB 16916.21 EN/IEC 61008-1

Product details

The Schneider Electric A9R82291 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 iID series, rated 100 A with 300 mA earth-leakage sensitivity. It's a Type AC, voltage-independent device — meaning the trip mechanism draws its energy from the fault current itself, not from a separate power supply, so it remains functional even if the line voltage drops. This makes it a straightforward choice for general-purpose protection on single-phase outgoing circuits in distribution boards.

The 100 A rated current (In) and 300 mA sensitivity cover most residential and light commercial sub-mains or feeder circuits where the load is resistive or lightly inductive — think water heaters, oven circuits, or general socket outlets. The 1500 A rated breaking capacity (Idm/Im) is adequate for downstream fault clearing in a typical TN or TT system, but if your fault current at the installation point exceeds that, you'll need an upstream MCB or fuse to coordinate.

The neutral is on the left, which matters for busbar alignment in a standard Acti9 distribution board.

Frequently asked questions

What is the A9R82291 used for?

It's a 2-pole residual current circuit breaker (RCCB) for earth-leakage protection on single-phase outgoing circuits, rated 100 A and 300 mA sensitivity.

What compliance standards does the A9R82291 meet?

It complies with GB 16916.21 and EN/IEC 61008-1, with IP20/IP40 protection per IEC 60529.