A9TDFD616 key specifications
ParameterValue
Control typeToggle
Network typeAC
Type of measurementVoltage Active power Current Power factor
Product or component typeActive arc fault detection RCBO
Threshold tripping voltage275 V for +/- 5 V
Voltage250 V AC 50 Hz between phase and neutral
[Ue] rated operational voltage230 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV
Breaking capacity10000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2
Current16 A
Breaking capacity codeH
Residual current tripping technologyVoltage independent

All specifications

A9TDFD616 additional specifications
ParameterValue
[Ics] rated service breaking capacity7500 A AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA AC 50 Hz conforming to EN/IEC 60947-2
Total power losses3.408 W
Power losses per pole2.65 W
Power losses on neutral0.763 W
Network frequency50 Hz
Poles description1P + N
Number of protected poles1
IP degree of protectionIP20 conforming to IEC 60529
Mounting modeClip-on
Mounting supportDIN rail
Cable entryTop and bottom
Wire stripping length14 mm
Connections - terminalsTunnel type terminal 1...16 mm² rigid Tunnel type terminal 1...10 mm² flexible
Pollution degree2 conforming to EN/IEC 62606
Relative humidity95 % at 55 °C
Operating altitude2000 m
Depth73 mm
Width36 mm
ColorWhite (RAL 9003)
Height91 mm
Electrical durability20000 cycles 230 V AC 50 Hz
Mechanical durability20000 cycles
StandardsEN/IEC 62606 EN/IEC 61009-1 EN/IEC 60947-2 EN/IEC 61009-2-1 BS EN 62606
RangeActi9
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Curve codeC
9 mm pitches4
TropicalisationSeverity B conforming to IEC 60068-2-30 for 28 d
Event managementOvervoltage Earth leakage Overload
Limitation class3
Local signallingON, OFF, fault trip LED arc fault diagnostic
Neutral positionLeft
Device short nameiCV40H ARC
Tightening torque2 N.m
Overvoltage categoryIII
Trip unit technologyThermal-magnetic
Magnetic tripping limit5...10 x In
Earth-leakage protectionIntegrated
Device location in systemOutgoer
Earth-leakage sensitivity30 mA
Electrical data recordingDate and time Maintenance indicators
Suitability for isolationYes
Concentrator compatibilityEcoStruxure Panel Server Advanced EcoStruxure Panel Server Entry EcoStruxure Panel Server Universal
Contact position indicatorYes
Locking options descriptionPadlocking device
Product specific applicationArc fault detection
Earth-leakage protection classType A-SI (Super Immunised)
Rated breaking and making capacityIdm 3000 A at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1
Ambient air temperature for storage-40...80 °C
Earth-leakage protection time delayInstantaneous
Ambient air temperature for operation-25...50 °C
Comb busbar and distribution block compatibilityYES