Schneider Electric A9TDND606 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9TDND606 Acti9 iCV40H ARC, 6 A, 1P+N, 10

MPNA9TDND606
Active

Schneider Electric Acti9 Active iCV40H ARC arc-fault detection device, 6 A, 1P+N, 10 kA Icn at 230 V AC, curve C, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9TDND606 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip LED arc fault diagnostic
A9TDND606 — Electrical Ratings
ParameterValue
Rated current (In)6 A
Rated operational voltage (Ue)230 V AC 50 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)250 V AC 50 Hz between phase and neutral
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability10000 cycles 230 V AC 50 Hz
Mechanical durability (operating cycles)20000 cycles
A9TDND606 — Identification
ParameterValue
Product nameActi9 Active iCV40 ARC
Product / component typeActive arc fault detection RCBO
Product range / familyActi9
Device short nameiCV40H ARC
A9TDND606 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal 1...16 mm² rigid Tunnel type terminal 1...10 mm² flexible
Wire stripping length14 mm
Terminal tightening torque2 N.m
Width36 mm
Height91 mm
Depth73 mm
A9TDND606 — Environmental
ParameterValue
Operating ambient temperature-25...50 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree2 conforming to EN/IEC 62606
Relative humidity95 % at 55 °C
Operating altitude2000 m
TropicalisationSeverity B conforming to IEC 60068-2-30 for 28 d
A9TDND606 — Approvals
ParameterValue
StandardsEN/IEC 62606 EN/IEC 61009-1 EN/IEC 61009-2-1

Product details

It is rated 6 A with a C trip curve and 10 kA Icn breaking capacity at 230 V AC, 50 Hz, conforming to EN/IEC 62606, EN/IEC 61009-1, and EN/IEC 61009-2-1. The thermal-magnetic trip unit handles both earth leakage and overload events, with local signalling via an LED for arc fault diagnostics and fault trip indication.

The 6 A rated current with curve C means it is sized for final circuits with moderate inrush — lighting, small appliances, or control loads — where the magnetic trip threshold (5 to 10 times In) avoids nuisance tripping on capacitive or motor-start currents. The 1P+N poles with neutral on the left suit single-phase final subcircuits in TN or TT systems.

This device is designed for final distribution boards in commercial and residential buildings where arc-fault protection is required by local codes (e.g., India, as noted in the targeted country). The top and bottom cable entry and 2 N.m tightening torque match typical panel-building practice.

Frequently asked questions

What is A9TDND606's listed depth (73 mm) on this component line?

The listed depth is 73 mm.

What is A9TDND606's listed range (Acti9) on this component line?

The range is Acti9, Schneider Electric's modular DIN-rail system for final distribution.

MPN
A9TDND606