Schneider Electric A9Z03440 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9Z03440 Acti9 ID K RCCB, 40 A, 300 mA, 4

MPNA9Z03440
Active

Schneider Electric Acti9 ID K, residual current circuit breaker (RCCB), 4P, 40 A, 300 mA, Type A, DIN-rail clip-on, voltage-independent tripping, EN/IEC 61008-1.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9Z03440 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9Z03440 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)380...415 V AC 50 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)440 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 2000 cycles
Mechanical durability (operating cycles)5000 cycles
A9Z03440 — Identification
ParameterValue
Product nameActi9 ID K
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameID K
A9Z03440 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsBiconnect top or bottom 1...35 mm² rigid Biconnect top or bottom 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height81 mm
Depth68 mm
A9Z03440 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-30...70 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
A9Z03440 — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN/IEC 61008-2-1

Product details

The Schneider Electric A9Z03440 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 ID K family, rated 40 A continuous and 300 mA earth-leakage sensitivity. Rated operational voltage is 380...415 V AC 50 Hz. Voltage-independent tripping technology detects earth faults even if line voltage collapses. Clip-on mounting to a standard 35 mm DIN rail, 72 mm wide (8 x 9 mm pitches), with terminals accepting up to 35 mm² rigid or 25 mm² flexible conductors. The IP20 body is rated for enclosed distribution boards; IP40 applies when fitted in a modular enclosure. For panel builders: strip 14 mm, torque to 3.5 N·m top or bottom.

Carries VDE quality label. Pollution degree 2 (normal, non-conductive pollution only). Impulse withstand voltage 4 kV, impulse current withstand 200 A (8/20 µs waveform).

Frequently asked questions

What is the A9Z03440's earth-leakage sensitivity and type?

300 mA sensitivity, Type A (detects sinusoidal and pulsating DC fault currents), instantaneous trip, voltage-independent tripping technology.

What standards does the A9Z03440 comply with?

EN/IEC 61008-1 and EN/IEC 61008-2-1. VDE certified. Pollution degree 2, impulse withstand 4 kV.