Skip to main content
Schneider Electric A9Z21263 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9Z21263 Acti9 iID RCCB, 63A, 30mA, 2P

MPNA9Z21263
Active

Schneider Electric Acti9 iID RCCB, A9Z21263, 2P, 63 A, 30 mA, Type A, 10 kA SCCR.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9Z21263 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9Z21263 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9Z21263 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9Z21263 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsDouble terminal front 1...35 mm² rigid Double terminal front 1...25 mm² flexible Double terminal front 1...25 mm² flexible with ferrule Double terminal back 1...25 mm² rigid Double terminal back 1...16 mm² flexible Double terminal back 1...16 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height91 mm
Depth73 mm
A9Z21263 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9Z21263 — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN/IEC 61008-2-1

Product details

The Schneider Electric A9Z21263 is an Acti9 iID residual current circuit breaker (RCCB) — a 2-pole, 63 A, 30 mA sensitivity device for AC networks at 50/60 Hz, rated 220...240 V AC.

The 63 A rated current matches the incoming supply for a sub-distribution board or a high-load final circuit. The Type A classification means it detects sinusoidal AC residual currents plus pulsed DC residual currents, covering modern loads with rectifiers (switch-mode supplies, variable-speed drives, LED drivers) that a simple AC-type RCCB would miss. The instantaneous trip means no intentional delay — it clears a ground fault within the natural response time of the voltage-independent trip mechanism, which does not rely on the line voltage to operate. The 73 mm depth and 91 mm height fit standard modular enclosure cutouts; the clip-on mounting snaps onto a DIN rail without tools. Terminals accept up to 35 mm² rigid or 25 mm² flexible conductors, with a stripping length of 14 mm and a tightening torque of 3.5 N·m — typical for a 63 A device in a panel.

Frequently asked questions

What is A9Z21263's earth-leakage sensitivity and type?

It is a 30 mA Type A RCCB, meaning it detects both sinusoidal AC and pulsed DC residual currents.

What is the rated breaking capacity of A9Z21263?

The rated conditional short-circuit current is 10 kA, and the rated breaking and making capacity (Idm/Im) is 1500 A.

Where can I buy A9Z21263 and how is it quoted?

The A9Z21263 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What compliance documentation does Schneider Electric provide for A9Z21263?

The device is certified to EN/IEC 61008-1 and EN/IEC 61008-2-1, with an IP20/IP40 degree of protection and a rated impulse withstand voltage of 6 kV.