Schneider Electric A9Z21263 Acti9 iID RCCB, 63A, 30mA, 2P

MPNA9Z21263
Active

Schneider Electric Acti9 iID RCCB, A9Z21263, 2P, 63 A, 30 mA, Type A, 10 kA SCCR.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9Z21263 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9Z21263 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9Z21263 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9Z21263 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsDouble terminal front 1...35 mm² rigid Double terminal front 1...25 mm² flexible Double terminal front 1...25 mm² flexible with ferrule Double terminal back 1...25 mm² rigid Double terminal back 1...16 mm² flexible Double terminal back 1...16 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height91 mm
Depth73 mm
A9Z21263 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9Z21263 — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN/IEC 61008-2-1

Product details

The Schneider Electric A9Z21263 is an Acti9 iID residual current circuit breaker (RCCB) — a 2-pole, 63 A, 30 mA sensitivity device for AC networks at 50/60 Hz, rated 220...240 V AC.

The 63 A rated current matches the incoming supply for a sub-distribution board or a high-load final circuit. The Type A classification means it detects sinusoidal AC residual currents plus pulsed DC residual currents, covering modern loads with rectifiers (switch-mode supplies, variable-speed drives, LED drivers) that a simple AC-type RCCB would miss. The instantaneous trip means no intentional delay — it clears a ground fault within the natural response time of the voltage-independent trip mechanism, which does not rely on the line voltage to operate. The 73 mm depth and 91 mm height fit standard modular enclosure cutouts; the clip-on mounting snaps onto a DIN rail without tools. Terminals accept up to 35 mm² rigid or 25 mm² flexible conductors, with a stripping length of 14 mm and a tightening torque of 3.5 N·m — typical for a 63 A device in a panel.

Frequently asked questions

What is A9Z21263's earth-leakage sensitivity and type?

It is a 30 mA Type A RCCB, meaning it detects both sinusoidal AC and pulsed DC residual currents.

What is the rated breaking capacity of A9Z21263?

The rated conditional short-circuit current is 10 kA, and the rated breaking and making capacity (Idm/Im) is 1500 A.

Where can I buy A9Z21263 and how is it quoted?

The A9Z21263 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What compliance documentation does Schneider Electric provide for A9Z21263?

The device is certified to EN/IEC 61008-1 and EN/IEC 61008-2-1, with an IP20/IP40 degree of protection and a rated impulse withstand voltage of 6 kV.

MPN