Skip to main content
Schneider Electric A9Z22291 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9Z22291 Acti9 iID RCCB, 100 A, 100 mA, T

MPNA9Z22291
Obsolete

Schneider Electric Acti9 iID RCCB, A9Z22291, 2P, 100 A, 100 mA sensitivity, Type A, DIN rail clip-on, EN/IEC 61008-1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9Z22291 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9Z22291 — Electrical Ratings
ParameterValue
Rated current (In)100 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durabilityAC-1: 10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9Z22291 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9Z22291 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsDouble terminal front 1...35 mm² rigid Double terminal front 1...25 mm² flexible Double terminal front 1...25 mm² flexible with ferrule Double terminal back 1...25 mm² rigid Double terminal back 1...16 mm² flexible Double terminal back 1...16 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height91 mm
Depth73 mm
A9Z22291 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9Z22291 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9Z22291 is an Acti9 iID RCCB — a 2-pole, 100 A device with 100 mA earth-leakage sensitivity, Type A protection, rated for 220-240 V AC 50/60 Hz.

Rated at 100 A continuous, this RCCB handles the full load of a main distribution board or a high-current sub-feed. The 100 mA sensitivity provides earth-fault protection while tolerating normal leakage from equipment like UPS systems or VFDs. The rated conditional short-circuit current is 10 kA. Breaking capacity is listed as Idm 1500 A and Im 1500 A — the RCCB's own making/breaking capacity for residual and overcurrent faults. The instantaneous trip (no intentional delay) means it clears earth faults quickly, which is the default for most RCCB applications unless selectivity with downstream devices is needed.

The IP20 finger-safe enclosure is standard for enclosed distribution boards; the IP40 rating applies when mounted in a modular enclosure. The toggle control and padlocking option allow lockout/tagout for maintenance.

Frequently asked questions

What is A9Z22291's depth?

The depth is 73 mm.

MPN
A9Z22291