Skip to main content
Schneider Electric A9Z32291 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9Z32291 Acti9 iID RCCB, 100 A, 100 mA, T

MPNA9Z32291
Obsolete

Schneider Electric Acti9 iID, A9Z32291, 2P residual current circuit breaker (RCCB), 100 A, 100 mA, Type A-SI, 10 kA.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9Z32291 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9Z32291 — Electrical Ratings
ParameterValue
Rated current (In)100 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durabilityAC-1: 10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9Z32291 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9Z32291 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsDouble terminal front 1...35 mm² rigid Double terminal front 1...25 mm² flexible Double terminal front 1...25 mm² flexible with ferrule Double terminal back 1...25 mm² rigid Double terminal back 1...16 mm² flexible Double terminal back 1...16 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height91 mm
Depth73 mm
A9Z32291 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9Z32291 — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN/IEC 61008-2-1

Product details

The Schneider Electric A9Z32291 is a 2-pole Acti9 iID residual current circuit breaker (RCCB) rated for 100 A continuous current with a 100 mA earth-leakage sensitivity. It is a Type A-SI (Super Immunised) device, meaning it is voltage-independent and designed to withstand high-frequency transient surges and pulsed DC currents that would nuisance-trip a standard Type A or AC RCCB. This makes it suitable for circuits with electronic loads, variable-speed drives, or LED lighting where smooth DC fault currents may be present. Terminals accept conductors up to 35 mm² rigid (top/bottom dual terminals), and the tightening torque is specified at 3.5 N.m.

The 100 A rated current (In) sets the continuous load capacity; this RCCB is sized for a main incoming supply or a heavy sub-feed in a distribution board. The 100 mA sensitivity is a delayed-action characteristic for earth-leakage protection — it is not a 30 mA personal-protection device, but rather a fire-protection or equipment-protection threshold, commonly specified for circuits supplying fixed equipment where a lower sensitivity would cause nuisance tripping from natural leakage. The Type A-SI classification (Super Immunised) per EN/IEC 61008-1 means the device can handle pulsed DC residual currents up to 10 mA and is immune to surge currents up to 3 kA (8/20 µs waveform) without tripping. This is critical for circuits containing single-phase rectifiers, switched-mode power supplies, or variable-frequency drives that generate smooth DC fault components.

The device is fully compliant with EN/IEC 61008-1 and EN/IEC 61008-2-1, the harmonized standards for residual current operated circuit breakers without integral overcurrent protection. The IP degree of protection is IP20 (device) and IP40 (modular enclosure).

Frequently asked questions

Where can I buy the A9Z32291?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote.

What is the A9Z32291's earth-leakage sensitivity?

The earth-leakage sensitivity is 100 mA, with a Type A-SI (Super Immunised) characteristic per EN/IEC 61008-1.

What compliance standards does the A9Z32291 meet?

It complies with EN/IEC 61008-1 and EN/IEC 61008-2-1, with an IP20/IP40 degree of protection and a rated impulse withstand voltage of 6 kV.

MPN
A9Z32291