Schneider Electric A9Z35291 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9Z35291 Acti9 iID RCCB, 100A 300mA Type

MPNA9Z35291
Obsolete

Schneider Electric Acti9 iID RCCB, A9Z35291, 2P, 100 A, 300 mA, Type A-SI, 10 kA.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9Z35291 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delaySelective
Residual-current tripping technologyVoltage independent
A9Z35291 — Electrical Ratings
ParameterValue
Rated current (In)100 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durabilityAC-1: 10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9Z35291 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9Z35291 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsDouble terminal front 1...35 mm² rigid Double terminal front 1...25 mm² flexible Double terminal front 1...25 mm² flexible with ferrule Double terminal back 1...25 mm² rigid Double terminal back 1...16 mm² flexible Double terminal back 1...16 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height91 mm
Depth73 mm
A9Z35291 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9Z35291 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

It is a 2-pole (2P) unit for AC networks, Type A-SI (Super Immunised) — meaning it handles pulsed DC residual currents and is selectively time-delayed to coordinate with downstream devices, reducing nuisance tripping on transient surges. Rated operational voltage is 220...240 V AC at 50/60 Hz, with an insulation voltage of 500 V AC and impulse withstand of 6 kV. The conditional short-circuit current rating is 10 kA, and the rated breaking/making capacity is Idm 1500 A / Im 1500 A — figures that govern its fault-clearing capability in a distribution board.

Clip-on mounting to DIN rail, 36 mm wide (4 x 9 mm pitches), 73 mm deep, 91 mm tall. Neutral on the left. IP20 finger-safe terminals; IP40 inside a modular enclosure. Pollution degree 3 (industrial environment). The toggle control and contact position indicator give clear visual status. Padlocking provision allows lockout/tagout.

The 8/20 µs impulse withstand of 3000 A per that standard confirms immunity to lightning-induced surges. Electrical durability is 10,000 cycles (AC-1); mechanical durability is 20,000 cycles.

Frequently asked questions

What is A9Z35291's listed range (Acti9) on this component line?

The A9Z35291 belongs to the Schneider Electric Acti9 range, specifically the iID series of residual current circuit breakers (RCCBs).

MPN
A9Z35291