Skip to main content
Schneider Electric ABT7PDU025G

Schneider Electric ABT7PDU025G

MPNABT7PDU025G
Obsolete

voltage transformer - 230..400 V - 2 x 115 V - 250 VA

$142.68 – $289.80Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ABT7PDU025G key specifications
ParameterValue
Range of productModicon Transformer Universal
Output protection typeAgainst overload, protection technology: with additional protection fuses or circuit-breakers in Selection of Protection Against overvoltage, protection technology: with additional protection fuses or circuit-breakers in Selection of Protection Against short-circuits, protection technology: with additional protection fuses or circuit-breakers in Selection of Protection
Product or component typeSafety and isolation transformer
Input voltage230 V AC single phase, terminal(s): N-L1 400 V AC phase to phase, terminal(s): L1-L2
Output voltage115/230 V AC
Input voltage limits207...253 V 360...440 V
Short-circuit voltage0,066
Input voltage tolerance+/- 15 V
Voltage variation at nominal load0,0313 at 230 V 0,0313 at 400 V
Maximum voltage drop at rated load3.37 %
Rated power in250 VA
Power dissipation in27.8 W

All specifications

ABT7PDU025G additional specifications
ParameterValue
Network frequency limits47...63 Hz
IP degree of protectionIP20
Connections - terminalsFor input connection: screw type terminals, connection capacity: 5 x 4 mm² AWG 11 For input ground connection: screw type terminals, connection capacity: 1 x 4 mm² AWG 11 For output connection: screw type terminals, connection capacity: 4 x 4 mm² AWG 11
Relative humidity0...95 % during operation
Operating altitude3000 m
Depth141.0 mm
Width123.0 mm
Height152.0 mm
StandardsUL 506
MarkingCE
Efficiency90 %
Status LED1 LED (orange) input voltage
Fixing modeBy 4 screws diameter: 6.5 mm on vertical panel, operating position: horizontal By 4 screws diameter: 6.5 mm on vertical panel, operating position: vertical By 4 screws diameter: 6.5 mm on horizontal panel with derating to 90 %
No load losses13.68 W
Output couplingParallel Grounding of secondary Series by internal jumper
Protective coverWith
Secondary windingDouble
Dielectric strength3200 V between input and ground 3200 V between output and ground 5100 V between input and output
Overvoltage categoryClass I conforming to VDE 0106-1
Electrical insulation classClass B
Environmental characteristicEMC conforming to IEC 62041 Safety conforming to EN 61558-1 Safety conforming to EN 61558-2-4
Output sustained overvoltage0,018 (no load, hot state)
Ambient air temperature for storage-40...80 °C
Ambient air temperature for operation-20...60 °C
MPN
ABT7PDU025G