Skip to main content
Schneider Electric ATS480C21Y

Schneider ATS480C21Y Altivar Soft Starter, 210 A, 3-phase

MPNATS480C21Y
Active

Schneider ATS480C21Y Basic Control Softstarters.

$4,001.94Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

ATS480C21Y key specifications
ParameterValue
Protection typePhase failure line Integrated thermal protection motor Thermal protection starter Current overload motor Underload motor Excessive starting time, locked rotor motor Motor phase loss motor Line supply phase loss line Line supply phase loss motor Thermal protection motor
Range of productAltivar Soft Starter ATS480
Relay output typeRelay outputs R1A 1 NO Relay outputs R1B 1 NO Relay outputs RIC NO/NC programmable
Discrete input typeSTOP) logic inputs, 3500 Ohm RUN) logic inputs, 3500 Ohm DI3) programmable as logic input, 3500 Ohm DI4) programmable as logic input, 3500 Ohm
Discrete output typeDQ1) programmable digital output DQ2) programmable digital output 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m
Product or component typeSoft starter
Ue power supply voltage208...690 V - 15...10 %
Coil voltage24 V DC
[Us] control circuit voltage110...230 V AC 50/60 Hz - 15...10 %
Maximum switching currentRelay outputs 2 A 250 V AC Relay outputs 2 A 30 V DC Relay outputs
Minimum switching current100 mA 12 V DC relay outputs
Rated current in heavy duty170.0 A at 104 °F (40 °C) heavy duty

All specifications

ATS480C21Y additional specifications
ParameterValue
[Ie] rated operational currentNormal duty 210.0 A 104 °F (40 °C))
Power loss static current independent25.0 W
[In] rated current pwr loss specifctn210.0 A
Current limiting %In (5 x ie maximum)150...700 %
Power loss per device current dependent560.0 W
Apparent power0.106 kVA
Motor power55.0 kW 230 V in the motor supply line normal duty 45.0 kW 230 V in the motor supply line heavy duty 110.0 kW 400 V in the motor supply line normal duty 90.0 kW 400 V in the motor supply line heavy duty 110.0 kW 440 V in the motor supply line normal duty 90.0 kW 440 V in the motor supply line heavy duty 132.0 kW 500 V in the motor supply line normal duty 110.0 kW 500 V in the motor supply line heavy duty 132.0 kW 525 V in the motor supply line normal duty 110.0 kW 525 V in the motor supply line heavy duty 160.0 kW 660 V in the motor supply line normal duty 132.0 kW 660 V in the motor supply line heavy duty 200.0 kW 690 V in the motor supply line normal duty 160.0 kW 690 V in the motor supply line heavy duty 110.0 kW 230 V to the motor delta terminals normal duty 90.0 kW 230 V to the motor delta terminals heavy duty 160.0 kW 400 V to the motor delta terminals normal duty 132.0 kW 400 V to the motor delta terminals heavy duty
Power supply frequency50...60 Hz - 20...20 %
Maximum horse power rating60.0 hp 208 V normal duty 50.0 hp 208 V heavy duty 75.0 hp 230 V normal duty 60.0 hp 230 V heavy duty 150.0 hp 460 V normal duty 125.0 hp 460 V heavy duty 200.0 hp 575 V normal duty 150.0 hp 575 V heavy duty
Phases3 phase
Utilisation categoryAC-3A AC-53A
IP degree of protectionIP00
Device connectionIn the motor supply line To the motor delta terminals
Maximum acceleration under shock load (during storage)100 m/s² at 11 ms
Maximum acceleration under shock load (during transport)100 m/s² at 11 ms
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13...200 Hz
StandardsIEC 60947-4-2 UL 60947-4-2 IEC 60664-1
MarkingCE CCC UKCA EAC RCM CULus
CategoryUS1CP1G22588
Option cardCommunication module Profibus DP V1 Communication module Modbus TCP/EtherNet/IP Communication module CANopen daisy chain Communication module CANopen Sub-D Communication module CANopen open style Communication module PROFINET
Device short nameATS480
Input compatibilitySTOP discrete input level 1 PLC IEC 61131-2 RUN discrete input level 1 PLC IEC 61131-2 DI3 discrete input level 1 PLC IEC 61131-2 DI4 discrete input level 1 PLC IEC 61131-2
Product destinationAsynchronous motors
Relay output number3
Discrete input logicProgrammable digital input < 5 V
Discrete input number4
Discrete output number2
Product specific applicationProcess and infrastructures
Motor thermal protection classClass 10E
Integrated motor overload protectionTrue
Maximum deflection under vibratory load (during storage)1.75 mm at 2...9 Hz
Maximum acceleration under vibratory load (during storage)15 m/s² at 200...500 Hz 10 m/s² at 9...200 Hz
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz
Maximum deflection under vibratory load (during transport)1.75 mm at 2...9 Hz
Maximum acceleration under vibratory load (during transport)15 m/s² at 200...500 Hz 10 m/s² at 9...200 Hz

Product details

Overview

The ATS480C21Y: It carries CE, CCC, UKCA, EAC, RCM and CULus markings and complies with IEC 60947-4-2 and UL 60947-4-2, suiting global panel approvals.

I/O count vs ATS22C59S6

The ATS480C21Y provides 4 discrete inputs and 2 discrete outputs, versus 3 inputs on the ATS22C59S6; the extra input allows a separate start/stop and a reset signal without multiplexing.

MPN