Skip to main content
Schneider Electric ATV320U15N4C412

Schneider Electric ATV320U15N4C412

MPNATV320U15N4C412
Active

Variable speed drive, Altivar Solar, 1.5kW, 380 to 500V, 3 phases, compact

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

ATV320U15N4C412 key specifications
ParameterValue
Protection typeInput phase breaks drive Overcurrent between output phases and earth drive Overheating protection drive Short-circuit between motor phases drive Thermal protection drive
Range of productAltivar Solar
Relay output typeConfigurable relay logic R1A 1 NO 100000 cycles Configurable relay logic R1B 1 NC 100000 cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO 100000 cycles Configurable relay logic R2C
Analogue input typeAI1 voltage 0...10 V DC 30 kOhm 10 bits AI2 bipolar differential voltage +/- 10 V DC 30 kOhm 10 bits AI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits
Discrete input typeSTO safe torque off, 24 V DC1.5 kOhm DI1...DI6 logic inputs, 24 V DC 30 V) DI5 programmable as pulse input 0...30 kHz, 24 V DC 30 V)
Analogue output typeSoftware-configurable current AQ1 0...20 mA 800 Ohm 10 bits Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits
Discrete output typeOpen collector DQ+ 0...1 kHz 30 V DC 100 mA Open collector DQ- 0...1 kHz 30 V DC 100 mA
Type of polarizationNo impedance
Product or component typeVariable speed drive
Maximum output voltage500 V
Supply voltage380...500 V - 15...10 %
Line current6.4 A 380 V heavy duty) 4.9 A 500 V heavy duty)

All specifications

ATV320U15N4C412 additional specifications
ParameterValue
Nominal output current4.1 A
Short-circuit protectionthermal protection
Maximum switching currentRelay output R1A, R1B, R1C resistive, cos phi = 1 3 A 250 V AC Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 30 V DC Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC Relay output R2A, R2C resistive, cos phi = 1 5 A 250 V AC Relay output R2A, R2C resistive, cos phi = 1 5 A 30 V DC
Maximum transient current6.2 A 60 s
Minimum switching currentRelay output R1A, R1B, R1C, R2A, R2C 5 mA 24 V DC
Maximum input current per phase6.4 A
Base load current at high overload3.0 A
Power factor0.491 at 380 V
Apparent power4.2 kVA 500 V heavy duty)
Motor power1.5 kW heavy duty
Power dissipation inFan 56.0 W 380 V 4 kHz
Network frequency50-60 Hz
Switching frequency2...16 kHz adjustable 4...16 kHz with derating factor
Maximum output frequency0.599 kHz
Nominal switching frequency4 kHz
Relative symmetric network frequency tolerance5 %
IP degree of protectionIP20
Communication port protocolModbus serial CANopen
Mounting modeWall mount
Electrical connectionScrew terminal 0.5...1.5 mm² analog input Screw terminal analog output Screw terminal
EMC filterClass C2 EMC filter integrated
Pollution degree2
Operating altitude3280.84...6561.68 ft (1000...2000 m) with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating
Permitted relative humidity (during operation)Class 3K5 according to EN 60721-3
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13...200 Hz
Depth6.2 in (158.0 mm)
Width4.1 in (105.0 mm)
Height5.6 in (142.0 mm)
StandardsIEC 61800-5-1
MarkingCE UR UKCA RCM
VariantStandard version
CategoryUS1CP4B22152
Data format8 bits, configurable odd, even or no parity
Noise level51 dB
Option cardcommunication module, Ethernet IP/Modbus TCP
Assembly styleWith heat sink
Braking torque170 % with braking resistor
Speed accuracy+/- 10 % of nominal slip 0.2 Tn to Tn
Regulation loopAdjustable PID regulator
Local signalling1 LED (red) for drive fault 1 LED (red) for CANopen error 1 LED (green) for CANopen run
Method of accessSlave CANopen
Operating positionVertical +/- 10 degree
Format of the driveCompact
Number of addresses1...247 1...127
Relay output number2
Discrete input logicPositive logic (source) Negative logic (sink)
Overvoltage categoryII
Prospective line isc5 kA
Transient overtorque170...200 % of nominal motor torque
Analogue input number3
Braking to standstillBy DC injection
Discrete input number7
Volume of cooling air4755.2 Gal/hr(US) (18.0 m3/h)
Analogue output number1
Discrete output number3
Motor slip compensationAutomatic whatever the load Adjustable 0...300 % Not available in voltage/frequency ratio (2 or 5 points)
Brake chopper integratedTrue
Product specific applicationPumping applications
4 quadrant operation possibleTrue
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
With sft fct safe stop 2 (SS2)False
Ambient air transport temperature-13...158 °F (-25...70 °C)
Synchronous motor control profileVector control without sensor
Asynchronous motor control profileVoltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
Acceleration and deceleration rampsLinear U S CUS Ramp switching Acceleration/deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection Automatic adaptation of ramp if braking capacity exceeded, by using resistor Linear adjustable separately from 0.01 to 6000 s
Ambient air temperature for storage-13...158 °F (-25...70 °C)
Ambient air temperature for operation14...122 °F (-10...50 °C) without derating 122...140 °F (50...60 °C) with derating factor
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3
With safety function safe stop 1 (SS1)True
With safety function safe positionFalse
With safety function safe directionFalse
With safety function safe torque offTrue
With safety function safe programmable logicFalse
With safety function safe speed monitorFalse
With safety function safe operating stopFalse
With safety function safely limited speedTrue
With safety function safely limited positionFalse
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz
MPN
ATV320U15N4C412