Skip to main content
Schneider Electric ATV630U15N4

Schneider ATV630U15N4 Process Drive, 1.5 kW, 4 A

MPNATV630U15N4
Active

Schneider Electric Altivar Process ATV630, ATV630U15N4, Standard version variable speed drive, 380…480 V, 4.0 A, 1.5 kW normal duty (0.75 kW heavy duty).

$455.93Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

ATV630U15N4 key specifications
ParameterValue
Type of coolingForced convection
Range of productAltivar Process ATV600
Discrete input typeDI7, DI8 programmable as pulse input 0...30 kHz, 24 V DC 1 MOhm 500 V DC for 1 minute to earth
Product or component typeVariable speed drive
Supply voltage380...480 V
Relative symmetric mains voltage tolerance10 %
Line current3 A 380 V normal duty) 2.6 A 480 V normal duty) 1.7 A 380 V heavy duty) 1.5 A 480 V heavy duty)
Nominal output current4.0 A
Continuous output current4 A 4 kHz normal duty 2.2 A 4 kHz heavy duty
Motor power1.5 kW normal duty) 0.75 kW heavy duty)
Maximum horse power rating2 hp normal duty 1 hp heavy duty
Supply frequency50...60 Hz - 5...5 %

All specifications

ATV630U15N4 additional specifications
ParameterValue
Speed drive output frequency0.1...500 Hz
Relative symmetric network frequency tolerance5 %
IP ratingUL type 1 UL 508C
IP degree of protectionIP21IEC 61800-5-1 IP21IEC 60529
Communication port protocolModbus TCP Ethernet Modbus serial
Mounting modeWall mount
EMC filterIntegrated 164.04 ft (50 m) IEC 61800-3 category C2 Integrated 492.1 ft (150 m) IEC 61800-3 category C3
Pollution degree2
Shock resistance15 gn 11 ms IEC 60068-2-27
Relative humidity5...95 % without condensation IEC 60068-2-3
Operating altitude1000...4800 m with current derating 1 % per 100 m
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Permitted relative humidity (during operation)Class 3K5 according to EN 60721-3
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13...200 Hz
StandardsUL 508C IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
MarkingCE
VariantStandard version
CategoryUS1CP4E22205
Noise level54.5 dB
Option cardSlot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module Slot A communication module, Ethernet IP/Modbus TCP/MD-Link communication module, BACnet MS/TP communication module, Ethernet Powerlink
Maximum THDI<48 % full load IEC 61000-3-12
Regulation loopAdjustable PID regulator
Safety functionSTO (safe torque off) SIL 3
Device short nameATV630
Operating positionVertical +/- 10 degree
Product destinationAsynchronous motors Synchronous motors
Overvoltage categoryIII
Discrete input number8
Volume of cooling air10038.7 Gal/hr(US) (38 m3/h)
Product specific applicationProcess and utilities
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Ambient air transport temperature-40...158 °F (-40...70 °C)
Ambient air temperature for storage-40...158 °F (-40...70 °C)
Ambient air temperature for operation5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz

Product details

The ATV630U15N4 is the standard variant of the Altivar Process ATV630 drive, sized for 380…480 V three-phase supply. It delivers 4.0 A continuous output at 4 kHz carrier, good for 1.5 kW normal-duty or 0.75 kW heavy-duty motor loads. An integrated EMC filter covers C2 compliance up to 50 m cable and C3 up to 150 m cable without an external filter. That saves panel space and a BOM line for most installations. STO (Safe Torque Off) rated SIL 3 is integrated, eliminating the need for an external safety relay.

Communications and I/O

Slot A supports plug-in communication modules for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen, BACnet MS/TP, or Ethernet Powerlink. Modbus TCP and Modbus serial are standard on the base unit. Eight discrete inputs are onboard, with DI7 and DI8 configurable as 0…30 kHz pulse inputs. A dual-slot relay extension and I/O extension cards are available for additional feedback or control.

The drive carries CE marking and complies with UL 508C, IEC 61800-3 (environments 1 and 2), IEC 61800-5-1, and IEC 61000-3-12. Rated for operation in 5…95 % RH non-condensing, 1000…4800 m altitude (derate 1 % per 100 m above 1000 m), and mounted vertically ±10°. Forced convection cooling moves 38 m³/h of air; noise level is 54.5 dB. Vibration resistance: 1.5 mm peak-peak at 2…13 Hz, 1 gn at 13…200 Hz per IEC 60068-2-6. Shock: 15 gn 11 ms per IEC 60068-2-27.

Frequently asked questions

What are the key electrical ratings of the ATV630U15N4?

It operates on 380…480 V AC, delivers 4.0 A continuous output (4 kHz carrier), and supports motor power of 1.5 kW normal duty or 0.75 kW heavy duty.

What compliance documentation does the ATV630U15N4 have?

It carries CE marking and complies with UL 508C, IEC 61800-3 (category C2/C3), IEC 61800-5-1, IEC 61000-3-12, and includes STO SIL 3 safety per IEC 61508 / IEC 13849-1.

What is the marking and variant of the ATV630U15N4?

The marking is CE and the variant is Standard version.