The ATV630U40M3 is an active-production Altivar Process ATV600 drive sized for 200-240 V three-phase supply, delivering 18.7 A continuous at 4 kHz (normal duty) or 13.7 A (heavy duty), corresponding to 4 kW and 3 kW motor power respectively. It ships without an internal EMC filter, so plan for an external filter or cabling mitigation if the installation must meet IEC 61800-3 Category C2 or C3 limits — the drive is certified to both environments, meaning the EMC performance depends on the filter you add. Wall-mount only, IP21 enclosure (UL Type 1), forced convection cooling drawing 38 m³/h of air. Mount vertical ±10°. Ambient humidity 5-95% non-condensing; altitude derating starts at 1000m, 1% per 100m up to 4800m. These bounds define where the drive can be panel-mounted without additional conditioning. Safety function STO (Safe Torque Off) integrated, SIL 3 capable. That eliminates a separate safety relay on many packaging lines with E-stops or guard interlocks. Discrete I/O includes 8 inputs, two programmable as 0-30 kHz pulse inputs, plus Modbus serial and Modbus TCP/Ethernet as standard communication ports.
The drive carries CE marking and is listed under UL 508C. It complies with IEC 61800-3 for both environment 1 category C2 and environment 2 category C3 — note that the as-shipped unit has no EMC filter, so achieving the lower emission limits will require an external filter. Additional standards covered: IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic current limits), IEC 60721-3 (environmental), IEC 61508 and IEC 13849-1 (functional safety). The variant is standard version.
Integration Notes
Wall-mount vertical ±10°, forced convection cooling at 38 m3/h; output frequency 0.1-500 Hz. Slots A and B accept communication modules (Profibus, PROFINET, DeviceNet, Modbus TCP, CANopen, Ethernet IP, BACnet MS/TP, Powerlink) or I/O/relay extensions.