Schneider Electric ATV650U30N4E
MPNATV650U30N4E
Active
variable speed drive, Altivar Process ATV600, ATV650, 3kW, 380 to 480V, IP55, disconnect switch
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
| Parameter | Value |
|---|---|
| Type of cooling | Forced convection |
| Range of product | Altivar Process ATV600 |
| Discrete input type | DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( 1 MOhm 500 V DC for 1 minute to earth |
| Product or component type | Variable speed drive |
| Supply voltage | 380...480 V |
| Relative symmetric mains voltage tolerance | 10 % |
| Line current | 5.1 A at 480 V (normal duty) 4.5 A at 380 V (heavy duty) 4 A at 480 V (heavy duty) 5.8 A at 380 V (normal duty) |
| Nominal output current | 7.2 A |
| Continuous output current | 5.6 A at 4 kHz for heavy duty 7.2 A at 4 kHz for normal duty |
| Motor power | 2.2 kW (heavy duty) 3 kW (normal duty) |
| Supply frequency | 50...60 Hz - 5...5 % |
| Speed drive output frequency | 0.1...500 Hz |
All specifications
| Parameter | Value |
|---|---|
| Relative symmetric network frequency tolerance | 5 % |
| IP degree of protection | IP55 conforming to IEC 60529 IP55 conforming to IEC 61800-5-1 |
| Communication port protocol | Modbus TCP Ethernet Modbus serial |
| Mounting mode | Wall mount |
| EMC filter | Integrated with 50 m conforming to IEC 61800-3 category C2 Integrated with 150 m conforming to IEC 61800-3 category C3 |
| Pollution degree | 3 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Relative humidity | 5...95 % without condensation conforming to IEC 60068-2-3 |
| Operating altitude | 1000...4800 m with current derating 1 % per 100 m <= 1000 m without derating |
| Vibration resistance | 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 |
| Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
| Standards | IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 |
| Marking | CE |
| Variant | With disconnect switch |
| Noise level | 52 dB |
| Option card | Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink Slot A: communication module, Profibus DP V1 |
| Maximum THDI | <48 % full load conforming to IEC 61000-3-12 |
| Regulation loop | Adjustable PID regulator |
| Safety function | STO (safe torque off) SIL 3 |
| Device short name | ATV650 |
| Operating position | Vertical +/- 10 degree |
| Product destination | Asynchronous motors Synchronous motors |
| Overvoltage category | III |
| Discrete input number | 8 |
| Product specific application | Process and utilities |
| Electromagnetic compatibility | Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 |
| Ambient air transport temperature | -40...70 °C |
| Ambient air temperature for storage | -40...70 °C |
| Ambient air temperature for operation | 40...50 °C (with derating factor) -15...40 °C (without derating) |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3 |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
MPN