Schneider Electric ATV6A0C80R4
MPNATV6A0C80R4
Active
Variable speed drive, Altivar Process ATV600, APM, single 440 V, 800 kW
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
| Parameter | Value |
|---|---|
| Protection type | Thermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive |
| Type of cooling | Forced convection |
| Range of product | Altivar Process ATV600 |
| Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits |
| Discrete input type | DI1...DI6 programmable, 24 V DC ( DI5, DI6 programmable as pulse input: 0...30 kHz, 24 V DC ( STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm |
| Analogue output type | Software-configurable voltage AO1, AO2: 0...10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AO1, AO2: 0...20 mA, resolution 10 bits |
| Type of polarization | No impedance for Modbus serial |
| Product or component type | Variable speed drive |
| Output voltage | <= power supply voltage |
| Supply voltage | 440 V - 15...10 % |
| Line current | 1216.0 A at 440 V (normal duty) 968.0 A at 440 V (heavy duty) |
All specifications
| Parameter | Value |
|---|---|
| Continuous output current | 1420.0 A at 2.5 kHz normal duty 1140.0 A at 2.5 kHz heavy duty |
| Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Maximum transient current | 1562 A during 60 s (normal duty) 1710 A during 60 s (heavy duty) |
| Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Permissible temporary current boost | 1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty) |
| Apparent power | 927 kVA at 440 V normal duty 738 kVA at 440 V heavy duty |
| Motor power | 800.0 kW at 440 V normal duty 630.0 kW at 440 V heavy duty |
| Power dissipation in | Forced convection: 21150 W, switching frequency 2.5 kHz (normal duty) Forced convection: 15270 W, switching frequency 2.5 kHz (heavy duty) |
| Supply frequency | 50...60 Hz - 5...5 % |
| Switching frequency | 2.5...8 kHz with derating factor 2...8 kHz adjustable |
| Frequency resolution | Display unit: 0.1 Hz Analog input: 0.012/50 Hz |
| Nominal switching frequency | 2.5 kHz |
| Speed drive output frequency | 0...500 Hz |
| Network number of phases | 3 phases |
| IP degree of protection | IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529 |
| Physical interface | 2-wire RS 485 for Modbus serial |
| Communication port protocol | Ethernet Modbus serial Modbus TCP |
| Mounting mode | Cabinet mount |
| Electrical connection | Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16 Line side: screw terminal Motor: M10 x 2 bars |
| EMC filter | Integrated with 300 m conforming to IEC 61800-3 category C3 |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Shock resistance | 7 gn for 11 ms conforming to IEC 60068-2-27 |
| Relative humidity | 5...95 % without condensation conforming to IEC 60068-2-3 |
| Operating altitude | 1000...4800 m with current derating 1 % per 100 m |
| Vibration resistance | 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 |
| Standards | IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 |
| Supply | External supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), <200 mA, protection type: overload and short-circuit protection |
| Marking | CE |
| Variant | Modular version |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output |
| Data format | 8 bits, configurable odd, even or no parity for Modbus serial |
| Noise level | 74 dB conforming to 86/188/EEC |
| Option card | Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module |
| Maximum THDI | <48 % full load conforming to IEC 61000-3-12 |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Exchange mode | Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP |
| Kit composition | 1 control unit mechanical mounting kits power connection set of fuses 5 power module 160 kW 4 front cover |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AO1, AO2: +/- 0.2 % for analog output |
| Safety function | STO (safe torque off) SIL 3 |
| Local signalling | 3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status |
| Method of access | Slave Modbus TCP |
| Device short name | ATV6A0 |
| Sampling duration | 2 ms +/- 0.5 ms (DI1...DI4) - discrete input 5 ms +/- 1 ms (DI5, DI6) - discrete input 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input 10 ms +/- 1 ms (AO1) - analog output |
| Transmission rate | 10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
| Transmission frame | RTU for Modbus serial |
| Input compatibility | DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2 DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2 |
| Number of addresses | 1...247 for Modbus serial |
| Product destination | Synchronous motors Asynchronous motors |
| Discrete input logic | Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1) Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1) Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) |
| Prospective line isc | 50 kA |
| Braking to standstill | By DC injection |
| Motor slip compensation | Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law |
| Number of preset speeds | 16 preset speeds |
| Environmental characteristic | Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3 |
| Product specific application | Process and utilities |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Synchronous motor control profile | Permanent magnet motor |
| Asynchronous motor control profile | Constant torque standard Variable torque standard Optimized torque mode |
| Acceleration and deceleration ramps | S, U or customized Linear adjustable separately from 0.01...9999 s |
| Ambient air temperature for storage | -40...70 °C |
| Ambient air temperature for operation | -10...40 °C without derating 40...50 °C with derating factor |
MPN