Schneider Electric ATV6B0C35R4
MPNATV6B0C35R4
Active
variable speed drive APM, ATV600, Low Harmonic drive, 400 V, 355 kW
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
| Parameter | Value |
|---|---|
| Protection type | Thermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive |
| Type of cooling | Forced convection |
| Range of product | Altivar Process ATV600 |
| Type of polarization | No impedance for Modbus serial |
| Product or component type | Variable speed drive |
| Output voltage | <= power supply voltage |
| Supply voltage | 440 V - 15...10 % |
| Line current | 503.0 A at 440 V (normal duty) 396.0 A at 440 V (heavy duty) |
| Continuous output current | 660.0 A at 2.5 kHz normal duty 520.0 A at 2.5 kHz heavy duty |
| Maximum transient current | 726 A during 60 s (normal duty) 780 A during 60 s (heavy duty) |
| Permissible temporary current boost | 1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty) |
| Apparent power | 383 kVA at 440 V normal duty 302 kVA at 440 V heavy duty |
All specifications
| Parameter | Value |
|---|---|
| Motor power | 355.0 kW at 440 V normal duty 280.0 kW at 440 V heavy duty |
| Power dissipation in | Forced convection: 14420 W, switching frequency 2.5 kHz (normal duty) Forced convection: 11470 W, switching frequency 2.5 kHz (heavy duty) |
| Supply frequency | 50...60 Hz - 5...5 % |
| Switching frequency | 2.5...8 kHz with derating factor 2...8 kHz adjustable |
| Frequency resolution | Display unit: 0.1 Hz Analog input: 0.012/50 Hz |
| Nominal switching frequency | 2.5 kHz |
| Speed drive output frequency | 0...500 Hz |
| Network number of phases | 3 phases |
| IP degree of protection | IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529 |
| Physical interface | 2-wire RS 485 for Modbus serial |
| Communication port protocol | Ethernet Modbus serial Modbus TCP |
| Mounting mode | Cabinet mount |
| Electrical connection | Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16 Line side: screw terminal Motor: M10 x 2 bars |
| EMC filter | Integrated with 300 m conforming to IEC 61800-3 category C3 |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Shock resistance | 4 gn for 11 ms conforming to IEC 60068-2-27 |
| Relative humidity | 5...95 % without condensation conforming to IEC 60068-2-3 |
| Operating altitude | 1000...4800 m with current derating above 1000m |
| Vibration resistance | 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 |
| Standards | IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 |
| Marking | CE |
| Variant | Modular version |
| Data format | 8 bits, configurable odd, even or no parity for Modbus serial |
| Noise level | 75 dB conforming to 86/188/EEC |
| Option card | Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module |
| Maximum THDI | <5 % full load conforming to IEEE 519 |
| Exchange mode | Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP |
| Kit composition | 1 control unit mechanical mounting kits power connection set of fuses 3.0 power module 160 kW 2.0 front cover |
| Safety function | STO (safe torque off) SIL 3 |
| Method of access | Slave Modbus TCP |
| Device short name | ATV6B0 |
| Transmission rate | 10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
| Transmission frame | RTU for Modbus serial |
| Number of addresses | 1...247 for Modbus serial |
| Product destination | Synchronous motors Asynchronous motors |
| Prospective line isc | 50 kA |
| Braking to standstill | By DC injection |
| Motor slip compensation | Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law |
| Environmental characteristic | Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3 |
| Product specific application | Process and utilities |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Synchronous motor control profile | Permanent magnet motor Synchronous reluctance motor |
| Asynchronous motor control profile | Constant torque standard Variable torque standard Optimized torque mode |
| Acceleration and deceleration ramps | S, U or customized Linear adjustable separately from 0.01...9999 s |
| Ambient air temperature for storage | -40...70 °C |
| Ambient air temperature for operation | -10...40 °C without derating 40...50 °C with derating factor |
MPN
ATV6B0C35R4