Schneider ATV930U22N4ZU VSD, 2.2 kW, 5.6 A

MPNATV930U22N4ZU
Active

ATV930U22N4ZU, a 3-phase variable speed drive from the Altivar Process ATV900 series, rated 380-480 V, 2.2 kW normal duty, 5.6 A continuous output, with integrated braking chopper and EMC filter.

$1,395.00 – $1,805.43Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

ATV930U22N4ZU key specifications
ParameterValue
Range of productAltivar Process ATV900
Type of polarizationNo impedance
Product or component typeVariable speed drive
Supply voltage380...480 V
Relative symmetric mains voltage tolerance10 %
Nominal output current5.6 A
Continuous output current5.6 A 4 kHz normal duty 4 A 4 kHz heavy duty
Motor power2.2 kW normal duty 1.5 kW heavy duty
Relative symmetric network frequency tolerance5 %
Phases3 phase
IP ratingUL type 12
IP degree of protectionIP21

All specifications

ATV930U22N4ZU additional specifications
ParameterValue
Communication port protocolModbus TCP EtherNet/IP Modbus serial
Mounting modeCabinet mount
Electrical connectionControl screw terminal 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal 2.5...6 mm² AWG 14...AWG 10 Motor screw terminal 2.5...6 mm² AWG 14...AWG 10 DC bus screw terminal 2.5...6 mm² AWG 14...AWG 10
EMC filterIntegrated With EMC plate option
Pollution degree2
Shock resistance15 gn 11 ms IEC 60068-2-27
Relative humidity5...95 % without condensation IEC 60068-2-3
Operating altitude1000...4800 m with current derating 1 % per 100 m
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Permitted relative humidity (during operation)Class 3K5 according to EN 60721-3
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13...200 Hz
StandardsUL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
SupplyExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm 500 V DC for 1 minute to earth
MarkingCE
VariantStandard version With braking chopper
CategoryUS1CP4E22276
Data format8 bits, configurable odd, even or no parity
Noise level54.5 dB
Maximum THDI<48 % full load IEC 61000-3-12
Exchange modeHalf duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Option moduleSlot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module EtherCAT Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module communication module Ethernet Powerlink
Assembly styleWith heat sink
Regulation loopAdjustable PID regulator
Transmission rate10, 100 Mbits 4.8 kbps 9600 bit/s 19200 bit/s
Device applicationIndustrial Application
Operating positionVertical +/- 10 degree
Number of addresses1...247
Product destinationSynchronous motors Asynchronous motors
Overvoltage categoryIII
Volume of cooling air10038.7 Gal/hr(US) (38 m3/h)
Environmental characteristicChemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3
Product specific applicationProcess for industrial
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Ambient air transport temperature-40...158 °F (-40...70 °C)
Ambient air temperature for storage-40...158 °F (-40...70 °C)
Ambient air temperature for operation5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz

Product details

Drive overview – what this order code delivers

The ATV930U22N4ZU is a current-production Altivar Process drive rated for 380…480 V three-phase input, 2.2 kW normal duty (1.5 kW heavy duty), with a continuous output of 5.6 A at 4 kHz switching frequency. It ships as the standard version with an integrated braking chopper, which handles resistive braking without an external module up to the drive's dissipation capacity. The logic supply expects 24 V DC (19…30 V) externally; an internal 24 V DC rail (21…27 V) powers the digital inputs and Safe Torque Off. An internal 10.5 V DC supply is available for a reference potentiometer (1-10 kΩ). The base unit includes Modbus TCP, EtherNet/IP, and Modbus serial. Slot A can accept fieldbus option modules (Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen); slots B and C accept I/O and encoder interface modules. The integrated EMC filter meets conducted emission limits for most industrial installations; an optional EMC plate upgrades performance for sensitive networks.

Compliance and lifecycle – what you can plan on

The part carries UL 508C listing, IEC 61800-3 (EMC environment), IEC 61800-5-1 (safety), and functional safety standards IEC 61508 / IEC 13849-1. Enclosure rating is IP21 with UL type 12. For cross-border procurement: the same genuine part carries identical compliance marks across regional variants. Warranty traceability to a specific local distributor may require a separate sourcing path – let me be transparent on that if needed.

Mounting and physical integration

Cabinet mount only, vertical orientation within ±10°. Requires minimum clearances for cooling: 38 m3/h (10038.7 Gal/hr(US)) of air flow – ensure unobstructed intake and exhaust around the heatsink. Operating altitude up to 1000 m without derating; up to 4800 m with 1 % current derating per 100 m above 1000 m. Vibrations: 1.5 mm pk-pk (2-13 Hz) / 1 gn (13-200 Hz). Shock: 15 gn / 11 ms. Power and motor connections accept 2.5-6 mm² (AWG 14-10) screw terminals. Control terminal block accepts 0.5-1.5 mm² (AWG 20-16).

Frequently asked questions

What is the supply voltage and phase requirement?

Three-phase input, 380 to 480 V AC. The drive also requires a 24 V DC external supply for the digital inputs.

What motor power does this drive support?

2.2 kW for normal-duty applications, 1.5 kW for heavy-duty (constant torque) profiles.

What compliance certifications are documented?

CE marked, UL 508C listed. Also compliant with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 61508, and IEC 13849-1.

What are the continuous output current ratings?

5.6 A at 4 kHz switching for normal duty; 4 A at 4 kHz for heavy duty.

MPN
ATV930U22N4ZU