Specifications

BDF16035 key specifications
ParameterValue
Control typeToggle
Product or component typeCircuit breaker
Voltage800 V IEC 60947-2
[Ue] rated operational voltage240 V AC 50/60 Hz UL 489
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Breaking capacity25 kA 208Y/120 V AC 50/60 Hz UL 489 25 kA 240 V AC 50/60 Hz UL 489 18 kA 480Y/277 V AC 50/60 Hz UL 489 14 kA 125 V DC 50/60 Hz UL 489 10 kA 600/347 V AC 50/60 Hz UL 489
Line rated current35 A
Breaking capacity codeD
Continuous current rating80 %
[Ics] rated service breaking capacity14 kA 220...240 V AC 50/60 Hz IEC 60947-2
Power wire stripping length0.8 in (20 mm)
Network frequency50/60 Hz

All specifications

BDF16035 additional specifications
ParameterValue
Poles1P
Protected poles description1t
Utilisation categoryCategory A
IK degree of protectionIK07 conforming to IEC 62262
IP degree of protectionFront cover IP40 IEC 60529
Mounting modeClip-on 35 mm symmetrical DIN rail) By screws plate)
Connection pitch1.06 in (27 mm)
Electrical connectionTerminal nut, ON and OFF end
Pollution degree3 IEC 60947-1
Operating altitude6561.68 ft (2000 m) without derating 5000 m with derating
ColorGray RAL 7016)
Depth3.1 in (80 mm)
Width1.06 in (27 mm)
Height5.4 in (137 mm)
Electrical durability10000 cycles IEC 947-1 Annex K ed 5.2 In
Mechanical durability15000 cycles IEC 947-1 Annex F ed 5.2
StandardsEN/IEC 60947-2 UL 489 GB 14048.2 EN/IEC 60947-5-1 NEMA AB1 NMX J-266 CSA C22.2 No 5
RangePowerPact
CategoryUS10DE201130
AWG gaugeAWG 14...AWG 8 aluminium/copper AWG 6...AWG 3/0 aluminium/copper
9 mm pitches3
Quality labelsCE
Trip unit nameTM-D
Quantity per setSet of 1
Device short nameBD 035
Tightening torque44.3 lbf.in (5 N.m) 0.004...0.02 in² (2.5...16 mm²) (AWG 14...AWG 4) 79.7 lbf.in (9 N.m) 0.04...0.1 in² (25...95 mm²) (AWG 3...AWG 3/0)
Device applicationDistribution
Trip unit technologyThermal-magneticTM-D,
Suitability for isolationYes IEC 60947-2
Circuit breaker applicationHACR rated
Ambient air temperature for storage-58...185 °F (-50...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)
MPN