Schneider Electric BGF26100

Schneider Electric BGF26100

MPNBGF26100
Active

Square D BGF26100 Molded Case Circuit|Square D BGF26100 Molded Case Circuit

$727.85Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

BGF26100 key specifications
ParameterValue
Control typeToggle
Product or component typeCircuit breaker
Voltage800 V IEC 60947-2
[Ue] rated operational voltage525 V AC 50/60 Hz UL 489
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Breaking capacity65 kA 208Y/120 V AC 50/60 Hz UL 489 65 kA 240 V AC 50/60 Hz UL 489 35 kA 480/277 V AC 50/60 Hz UL 489 35 kA 480 V AC 50/60 Hz UL 489 18 kA 250 V DC UL 489 18 kA 600Y/347 V AC 50/60 Hz UL 489
Line rated current100 A
Breaking capacity codeG
Continuous current rating80 %
[Ics] rated service breaking capacity65 kA 220...240 V AC 50/60 Hz IEC 60947-2 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 35 kA 440 V AC 50/60 Hz IEC 60947-2
Power wire stripping length0.8 in (20 mm)
Network frequency50/60 Hz

All specifications

BGF26100 additional specifications
ParameterValue
Poles2P
Protected poles description2t
Utilisation categoryCategory A
IK degree of protectionIK07 conforming to IEC 62262
IP degree of protectionFront cover IP40 IEC 60529
Mounting modeClip-on 35 mm symmetrical DIN rail) By screws plate)
Connection pitch1.06 in (27 mm)
Electrical connectionTerminal nut, ON and OFF end
Pollution degree3 IEC 60947-1
Operating altitude6561.68 ft (2000 m) without derating 5000 m with derating
ColorGray RAL 7016)
Depth3.1 in (80 mm)
Width2.1 in (54 mm)
Height5.4 in (137 mm)
Electrical durability10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Mechanical durability15000 cycles IEC 947-1 Annex K ed 5.2
StandardsNMX J-266 EN/IEC 60947-5-1 NEMA AB1 UL 489 GB 14048.2 EN/IEC 60947-2 CSA C22.2 No 5
RangePowerPact
CategoryUS10DE201131
AWG gaugeAWG 14...AWG 8 aluminium/copper AWG 6...AWG 3/0 aluminium/copper
9 mm pitches6
Quality labelsCE
Trip unit nameTM-D
Number of slots1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in)
Local signallingPresence of auxiliary contacts flag green)
Quantity per setSet of 1
Device short nameBG 100
Tightening torque44.3 lbf.in (5 N.m) 0.004...0.02 in² (2.5...16 mm²) (AWG 14...AWG 4) 79.7 lbf.in (9 N.m) 0.04...0.1 in² (25...95 mm²) (AWG 3...AWG 3/0)
Device applicationDistribution
Trip unit technologyThermal-magneticTM-D,
Suitability for isolationYes IEC 60947-2
Circuit breaker applicationHACR rated
Ambient air temperature for storage-58...185 °F (-50...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)