Schneider Electric C080N45EFM — Miniature Circuit Breakers (MCB)

Schneider Electric C080N45EFM ComPacT NS, 800 A, 4P, MicroLo

MPNC080N45EFM
Active

Schneider Electric ComPacT NS new generation, C080N45EFM, 800 A at 50 °C, 4-pole, MicroLogic 5.0 E electronic trip unit, 50 kA Icu at 415 V AC, fixed mount, backplate.

$2,994.07Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C080N45EFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C080N45EFM — Ratings
ParameterValue
Rated current (In)800 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory B
Overvoltage categoryIII
C080N45EFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C080N45EFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C080N45EFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C080N45EFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C080N45EFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLSI

Product details

It is a 4-pole, 800 A frame, manually operated unit with a fixed mount on a backplate — sized for a distribution panel main or a large feeder. The MicroLogic 5.0 E electronic trip unit provides LSI protection (overload, short-time short-circuit, instantaneous) plus an integrated energy meter, and the LCD display lets you read real-time metering and trip data without a separate panel meter. Rated 800 A at 50 °C, it carries a 50 kA Icu breaking capacity at 415 V AC (the N code), with higher ratings at lower voltages — 85 kA at 240 V, and still 30 kA at 690 V. That puts it in the middle of the NS frame's interrupting range: enough for most industrial distribution boards without over-specifying.

Mechanical durability is 10,000 cycles, electrical durability ranges from 2,000 cycles at 690 V In to 6,000 cycles at 440 V In/2 — adequate for a main breaker that sees infrequent switching. The 20-minute thermal memory means the trip curve accounts for prior heating, so nuisance trips on reclose after a warm overload are less likely.

The electronic trip unit (MicroLogic 5.0 E) includes an energy meter function — useful for sub-metering without an extra transducer. The LCD display and four red fault LEDs plus one yellow overload LED give local indication without opening the panel door.

Frequently asked questions

What is the breaking capacity of C080N45EFM at 415 V?

50 kA Icu at 380/415 V AC, 50/60 Hz, per IEC 60947-2. That is the N breaking capacity code.

What trip unit does C080N45EFM use?

It uses a MicroLogic 5.0 E electronic trip unit with LSI protection (overload, short-time short-circuit, instantaneous) and an integrated energy meter.

Where can I buy C080N45EFM?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.