Schneider Electric C100H32AFM — Miniature Circuit Breakers (MCB)

C100H32AFM ComPacT NS 1000A MCCB, 85 kA at 240V

MPNC100H32AFM
Active

Schneider Electric ComPacT NS new generation, C100H32AFM, manually operated 3P MCCB, 1000 A at 50 °C, MicroLogic 2.0 A electronic trip, 85 kA Icu at 240 V AC.

$4,252.86Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C100H32AFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C100H32AFM — Ratings
ParameterValue
Rated current (In)1000 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)52 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 52 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 48 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 31 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory B
Overvoltage categoryIII
C100H32AFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C100H32AFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C100H32AFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C100H32AFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C100H32AFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLI

Product details

What this 1000 A MCCB covers

The Schneider Electric C100H32AFM is a fixed-mount, manually operated 3-pole MCCB from the ComPacT NS new generation line, rated 1000 A at 50 °C and fitted with a MicroLogic 2.0 A electronic trip unit providing L (long-time overload) and I (instantaneous short-circuit) protection per EN/IEC 60947-2. The LCD display and ammeter measurement let you read load current directly off the front, which saves reaching for a clamp meter during a quick panel walk.

The 1000 A frame with MicroLogic 2.0 A gives you a 20-minute thermal memory — after a trip, it remembers the prior heat profile so re-closing too soon on a still-warm bus won't nuisance-trip again. Utilisation category B means it's designed for distribution, not direct motor starting — the electrical endurance of 2000 cycles at full rated current reflects that. For a motor circuit you'd want a contactor ahead of this breaker.

Dimensions are 327 mm high, 210 mm wide, 147 mm deep — fits standard switchgear cubicle compartments; the IK07 impact rating means it survives the odd dropped tool during installation.

Four red LEDs for fault indication and one yellow for overload give a quick visual on what caused the trip without needing to interrogate the trip unit.

Frequently asked questions

What is the breaking capacity of the C100H32AFM?

85 kA Icu at 240 V AC, 70 kA at 415 V AC, 65 kA at 440 V, 50 kA at 500/525 V, and 42 kA at 660/690 V — all per IEC 60947-2. The 70 kA at 415 V is the code H rating.

What trip unit does the C100H32AFM use?

It uses a MicroLogic 2.0 A electronic trip unit providing long-time overload (L) and instantaneous short-circuit (I) protection. It includes a 20-minute thermal memory and an LCD ammeter display.

Where can I buy the C100H32AFM?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.